background image

16

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX MERIT

®

 SERIES B-VENT GAS FIREPLACES   •   36" LMBV MODELS   •   CARE AND OPERATION INSTRUCTIONS

TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM

SymPTOm

POSSIblE CAUSES

CORRECTIvE ACTION

Ensure damper control lever is locked in the open position, all the way to the 

right.  If the damper control lever is locked in the open position troubleshoot 

through Steps B., C. and D. below.  If the main burner will still not light, deter-

mine if the damper switch is defective and replace if necessary.

See Below.

Reset the limit switch button.  If still not working, access the leads attached to the 

limit switch and check for continuity.  If no continuity, replace limit switch.

Disconnect the two black wires from the wire nuts. Test switch(s) for continu-

ity with a multimeter. If continuity is not indicated, switch(s) is defective and 

must be replaced.

Note: Before replacing “OFF/ON” switch, be sure to check wiring for loose 

connections or broken wires and repair as needed.

Check main burner orifice(s) for stoppage. Clean or replace.

Check vent system for obstructions.  

A. 

 Damper closed or 

Damper Switch defective.

b.

  Faulty Valve System.

C.

  Faulty limit switch.

D.

  “OFF/ON” or wall switch 

defective.

A.

  Burner orifice plugged.

b.

  Obstructed vent system.

1.

  Burner will not light.

2. 

Burners come “ON” but 

go “OFF.”

Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON” position.

Important: Valve system troubleshooting should only be accomplished by a qualified service technician.

• Turn Off Gas Supply

• Assure Valve Switch Is In ON Position

• Disconnect Control Harness

• Set Thermostat To Call For Heat

• Check For Proper Voltage At Control Harness

  (See Insert A).  Voltage Should Be 24V

  Between Thermostat Or Pressure Switch

  And 24V Common And 24V Hot.

• Line Voltage Power

• Low Voltage Transformer

• Limit Controller

• Thermostat

• Wiring

2

CHECK

START

NO

• Plug Control Harness Into Valve.  Wait For

   Internal Check Delay.

YES

• Igniter Warms Up And Glows Red.

• With Pilot Burner Cable Connected, Measure

   Voltage At Valve HSI Element Output.  24V

   Nominal.  (See Insert B)

NO

• Replace Igniter/Flame Rod Assembly.

YES

• Replace Valve.

NO

• Turn On Gas Supply.    • Pilot Burner Lights.

• Check That Pilot Gas Is Flowing.  Wait To

   Assure Plot Gas Tubing Is Purged.  Recycle

   Call For Heat If Necessary.

NO

YES

NO

YES

YES

1

• Measure Voltage Between 24V Hot And 24V Common

  Leads To Valve Control.  Must Measure At Least 19.5

  VAC With Igniter Powered (See Insert A).  To Identify

  Proper Lead, This Check Must Be Done With The

  Valve Control Connected And Igniter Powered.

• Check Transformer And

   Line Volt Supply.

NO

• Replace Pilot Assembly.

YES

• Check That Pilot Flame Makes Good Contact With

   Pilot Burner Flame Rod.

• Check For Good Electrical Connection Through The

   Pilot Tubing.

• If Both Of The Above Are Good, Replace Igniter/Flame

   Rod Assembly.

• Cycle Thermostat Off And Back On.

YES

• Main Valve Opens And Main Burner Lights.

NO

YES

• System Is Okay.

YES

• Main Burner Lights.

NO

2

1

Igniter Will Cycle Off And Back On Once During

The 90 Second Ignition Trial.  All Voltage

Measurements Must Be Taken While The Igniter

Is Powered.

When Measured Voltage At Connections, Use

Care To Assure Terminals Are Not Damaged.

• Replace Valve.

• Replace Valve.

24 Volt Hot

End View Of

Control Harness

Connector

24 Volt

Common

24 Volt

Switched

Check For Damaged Or Missing Terminals

In Connector

Insert A

Igniter Terminals

Insert B

2

1

Содержание Merit LMBV-36REN

Страница 1: ...on ou pour viter tout dommage mat riel toute blessure ou la mort This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by...

Страница 2: ...ns and cleanings may be required due to excessive lint from carpeting bedding material etc It is imperative that the control compartment burners and circulating airpassagewaysoftheappliancebekeptclean...

Страница 3: ...g are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Turn off the gas sup ply to the appliance and have it serviced by a qualified profe...

Страница 4: ...tructions respectively Millivoltandelectronicappliance lighting instructions may also be found on the pulloutlabelsattachedtothegascontrolvalve located within the gas control compartment If your appli...

Страница 5: ...ed Thedamperleveractuatesaswitch seewiring diagram which will prevent the appliance main burnerfromlightingunlessthedamperislocked open The appliance flue damper must always remain open when operating...

Страница 6: ...la casa 2 Si se usa un control remoto para controlar la chimenea encuentre el transmisor y l mpielo bien para quitar el polvo y aceite Pegue la etiqueta en la superficie del transmisor Figura B Selecc...

Страница 7: ...performed Important Turn off gas and any electrical power before servicing the appliance Millivolt Appliance Checkout The pilot flame should be steady not lifting or floating Flame should be blue in...

Страница 8: ...eaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacing Rockwool Ember Materials Qualified Service...

Страница 9: ...y hot and will remain hot up to one hour after gas supply is turned off Handle only when logs are cool Turnoffallelectricitytotheap pliance before you install grate and logs Warning This appliance is...

Страница 10: ...ment Only If any of the original wire as supplied must be replaced it must be replaced with Type AWM 200 C 18 GA wire Thermopile TH TP TH TP Limit Switch Damper Switch BK BK BK BK WHT 1 If any of the...

Страница 11: ...ontinue to hold the control knob in for about 1 minutes after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 8 If knob does not pop...

Страница 12: ...en utilisant le t l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le service des incendies C N utilisez que votre main pour manipuler le bouton de r glage du gaz...

Страница 13: ...ian to inspect the appliance and to replace any part of the control system and any gas control which has been under water Lighting Instructions Electronic 1 For complete shut down turn remote wall swi...

Страница 14: ...te plaque 2 Tournez l interrupteur mural la position d arr t OFF 3 Ouvrez la porte du compartiment de contr le du bas 4 Assurez vousquelasoupaped arr tdelacanalisationprincipale est ouverte 5 Tournez...

Страница 15: ...gap measures 1 8 replace pilot Figure 9 Check inlet gas pressure It should be within the limits as marked on the rating plate Clean or replace pilot orifice Checkpilotflame itmustimpingeonthermogenera...

Страница 16: ...sition Disconnect Control Harness Set Thermostat To Call For Heat Check For Proper Voltage At Control Harness See Insert A Voltage Should Be 24V Between Thermostat Or Pressure Switch And 24V Common An...

Страница 17: ...iance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation o...

Страница 18: ...as been sent The Model RCL is designed to operate with all millivolt ignition systems as well as electronic ignition systems It may be installed with use for either natural or propane gas appliances T...

Страница 19: ...4L58 1 24 Piezo Ignitor 10K86 1 10K86 1 25 Ignition Cable H5047 1 H5047 1 26 Pilot Tube 74L56 1 74L56 1 Natural Propane No DESCRIPTION Part No Qty Part No Qty Gas Fireplace Assembly 1 Firescreen H4167...

Страница 20: ...23 21 REF 10 26 22 24 25 14 14 REF 9 15 Printed in U S A 2006 by Lennox Hearth Products P N 875033M REV C 07 2010 Lennox Hearth Products reserves the right to make changes at any time without notice...

Отзывы: