background image

4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX MERIT

®

 SERIES B-VENT GAS FIREPLACES   •   36" LMBV MODELS   •   CARE AND OPERATION INSTRUCTIONS

CAUTION: DO NOT ATTEmPT TO TOUCH THE 

DOORS  WITH  yOUR  HANDS  WHIlE  THE 

FIREPlACE IS IN USE. AlWAyS USE DOOR 

HANDlES. DOORS WIll bECOmE vERy HOT 

WHEN FIREPlACE IS IN USE.

CAUTION: NEvER OPERATE THIS APPlIANCE 

WITH A bROkEN OR DAmAGED GlASS DOOR.  

REmOvE OR REPlACE ANy bROkEN GlASS 

DOOR COmPONENT bEFORE OPERATION.

Figure 3

Figure 2

3.

 Keep lower control compartment clean by 

vacuuming or brushing at least twice a year. 

More frequent cleaning may be required due to 

excessive lint from carpeting, bedding materials, 

etc. It is important that control compartments, 

burners and circulating air passageways of the 

appliance be kept clean and clear of obstruction 

of ventilating and combustion air.

4.

  Always  turn  off  gas  to  the  pilot  (millivolt 

appliances) before cleaning. Before re-lighting, 

refer to the lighting instructions in this manual. 

Instructions are also found on a pull-out panel 

located on the floor of the appliance.

5.

 Always keep the appliance area clear and 

free from combustible materials, gasoline and 

other flammable liquids.

6.

  Remember,  Millivolt  appliances  have  a 

continuous burning pilot flame. Exercise cau-

tion  when  using  products  with  combustible 

vapors.

7.

 Clean the optional glass doors only when 

necessary.  Wipe surface with clean, dampened, 

soft cloth.  Follow with dry, soft towel as desired.  

Take care not to scratch the glass surface.

Honeywell Electronic

 Gas Valve

Figure 4

ON/OFF Switch

Electronic

Gas Control

Valve

Inlet

Pressure

Port

Manifold Pressure Port

OFF

IN

P

S

I

ON

CONTROL

IG

N

IT

ER

Fully Open or

Fully Closed

To light electronic appliances refer to the detailed 

lighting instructions found in both English and 

French on pages 13 and 14 of these instructions 

respectively.  

millivolt and electronic appliance 

lighting instructions may also be found on the 

pull out labels attached to the gas control valve 

located within the gas control compartment

.  

If your appliance is equipped with an optional 

remote wall switch or remote control kit the 

appliance main burner may be turner on and off 

with the wall switch or remote control.  If the 

appliance is not equipped with a wall switch or 

remote control, the main burner must be turned 

off and on with the gas control switch. Toggle 

the switch from ON to OFF to operate the main 

burner from ON to OFF.  

2.

 When lit for the first time, this appliance will 

emit a slight odor for an hour or two. This is due 

to the “burn-in” of internal paints and lubricants 

used in the manufacturing process.

DAmPER AND COmbUSTION AIR CONTROlS

This appliance is fitted with a manually controlled 

vent damper.  The vent damper should be closed 

when the appliance is not in use to prevent cold 

air from entering the home through the venting 

system.  The damper is controlled through the 

use of a control lever located within the appli-

ance opening at the top center in front of the 

firebox lintel 

(

see Figure 5

 )

.  

WARNING:  DO  NOT  USE  AbRASIvE 

ClEANERS. NEvER ClEAN THE GlASS 

WHEN IT IS HOT. 

WARNING:    FIREPlACES  EQUIPPED 

WITH  OPTIONAl  ACCESSORy  DOORS 

SHOUlD bE OPERATED ONly WITH THE 

DOORS FUlly OPEN OR FUlly ClOSED 

(

FIguRe 4 

).  THIS APPlIANCE mAy ONly 

bE FITTED WITH DOORS CERTIFIED FOR 

USE WITH THE APPlIANCE.

AvERTISSEmENT:  POUR  UTIlISATION 

UNIQUEmENT  AvEC  lES  PORTES  EN 

vERRE CERTIFIêES AvEC l'APPAREIl.

E

A

TPTH

TP

TH

PILO

T

PIL

OT

ON

i

t

OFF

SIT Millivolt Valve

Gas Control

Knob

Piezo

Ignitor

WARNING:  DO NOT STRIkE OR SlAm 

SHUT OPTIONAl GlASS DOORS.

WARNING:  REPlACE  ANy  SAFETy 

SCREEN  OR  GUARD  REmOvED  FOR 

SERvICING  AN  APPlIANCE  PRIOR  TO 

OPERATING THE APPlIANCE.

WARNING:  DO  NOT  ATTEmPT  TO  RE-

PAIR  bROkEN  GlASS  COmPONENTS.  

REPlACE  ANy  bROkEN  DOORS  ONly 

WITH COmPlETE DOOR kITS, ObTAINED 

FROm lENNOx.  REmOvE ANy bROkEN 

GlASS PIECES by vACUUmING THEm 

OUT COmPlETEly.

Содержание Merit LMBV-36REN

Страница 1: ...on ou pour viter tout dommage mat riel toute blessure ou la mort This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by...

Страница 2: ...ns and cleanings may be required due to excessive lint from carpeting bedding material etc It is imperative that the control compartment burners and circulating airpassagewaysoftheappliancebekeptclean...

Страница 3: ...g are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Turn off the gas sup ply to the appliance and have it serviced by a qualified profe...

Страница 4: ...tructions respectively Millivoltandelectronicappliance lighting instructions may also be found on the pulloutlabelsattachedtothegascontrolvalve located within the gas control compartment If your appli...

Страница 5: ...ed Thedamperleveractuatesaswitch seewiring diagram which will prevent the appliance main burnerfromlightingunlessthedamperislocked open The appliance flue damper must always remain open when operating...

Страница 6: ...la casa 2 Si se usa un control remoto para controlar la chimenea encuentre el transmisor y l mpielo bien para quitar el polvo y aceite Pegue la etiqueta en la superficie del transmisor Figura B Selecc...

Страница 7: ...performed Important Turn off gas and any electrical power before servicing the appliance Millivolt Appliance Checkout The pilot flame should be steady not lifting or floating Flame should be blue in...

Страница 8: ...eaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacing Rockwool Ember Materials Qualified Service...

Страница 9: ...y hot and will remain hot up to one hour after gas supply is turned off Handle only when logs are cool Turnoffallelectricitytotheap pliance before you install grate and logs Warning This appliance is...

Страница 10: ...ment Only If any of the original wire as supplied must be replaced it must be replaced with Type AWM 200 C 18 GA wire Thermopile TH TP TH TP Limit Switch Damper Switch BK BK BK BK WHT 1 If any of the...

Страница 11: ...ontinue to hold the control knob in for about 1 minutes after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 8 If knob does not pop...

Страница 12: ...en utilisant le t l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le service des incendies C N utilisez que votre main pour manipuler le bouton de r glage du gaz...

Страница 13: ...ian to inspect the appliance and to replace any part of the control system and any gas control which has been under water Lighting Instructions Electronic 1 For complete shut down turn remote wall swi...

Страница 14: ...te plaque 2 Tournez l interrupteur mural la position d arr t OFF 3 Ouvrez la porte du compartiment de contr le du bas 4 Assurez vousquelasoupaped arr tdelacanalisationprincipale est ouverte 5 Tournez...

Страница 15: ...gap measures 1 8 replace pilot Figure 9 Check inlet gas pressure It should be within the limits as marked on the rating plate Clean or replace pilot orifice Checkpilotflame itmustimpingeonthermogenera...

Страница 16: ...sition Disconnect Control Harness Set Thermostat To Call For Heat Check For Proper Voltage At Control Harness See Insert A Voltage Should Be 24V Between Thermostat Or Pressure Switch And 24V Common An...

Страница 17: ...iance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation o...

Страница 18: ...as been sent The Model RCL is designed to operate with all millivolt ignition systems as well as electronic ignition systems It may be installed with use for either natural or propane gas appliances T...

Страница 19: ...4L58 1 24 Piezo Ignitor 10K86 1 10K86 1 25 Ignition Cable H5047 1 H5047 1 26 Pilot Tube 74L56 1 74L56 1 Natural Propane No DESCRIPTION Part No Qty Part No Qty Gas Fireplace Assembly 1 Firescreen H4167...

Страница 20: ...23 21 REF 10 26 22 24 25 14 14 REF 9 15 Printed in U S A 2006 by Lennox Hearth Products P N 875033M REV C 07 2010 Lennox Hearth Products reserves the right to make changes at any time without notice...

Отзывы: