Table 5. Advanced Settings
MENU
SETTING (default is bold)
Notes:
High Balance Point: 50°F (-17 to 75°F).
Adjustments are in increments of 1°F (0.56°C).
This setting is used to prevent the furnace or
electric heat from heating the structure. (Alert
19 - Minor - Notification only - The outdoor
temperature is higher than the level where the
furnace or electric heat is programmed to heat
the home.)
TEMPERATURE CONTROL MODE
Normal and
Comfort
The Feels-Like feature factors in the outdoor
temperature and indoor humidity for a more
accurate control of the temperature in the
home. Either an outdoor temperature sensor
is used or Internet Weather is enabled for this
feature to operate. Modifying this setting here
will also change the feature status on the user
settings screen.
• Normal - This setting cools or heats the
home to the desired temperature setting
(Feels Like is OFF.
• Comfort - This setting cools or heats the
home to the desired temperature setting
(Feels Like) is ON. When set to ON, other
parameters are modified to optimal settings
for this feature. Those setting changes
will be listed on-screen when Comfort is
enabled.
Default is Comfort.
WALL INSULATION
Poor,
Average
and Good
Poor, Average and Good represents the
insulation form factor value considered for
temperature anticipation value
DEADBAND
Adjustable (3 to 8 degrees)
Prevents the Heating and Cooling from being
set closer together than 3 degrees or greater
than 8 degrees (Dead- band).
Default is 3
⁰