16
Table 5. Advanced Settings
MENU
SETTING (default is bold)
Notes:
SYSTEM SETUP
Humidifier
Not Installed
These options only appear under System
Setup if the H/D and ACC terminals have been
enabled for the specific type of accessory.
Go to Terminal Settings to enabled attached
accessory for the specific terminal being used.
Humidification
Dehumidifier
Not Installed
Humiditrol - Min
Humiditrol - Mid
Humiditrol - Max
Auxiliary Dehumidifier
The Humiditrol settings provides adjustment of Humiditrol overcooling operation. Overcooling
from two degrees below the cooling set point down to two degrees above the heating set point
is provided. The minimum overcooling of two degrees below the cooling set point is represented
by “MIN”. The maximum overcooling of two degrees above the heating set point or 65
°
F is
represented by “MAX”. Halfway between is represented by “MID”. The default is “MAX”
.
OUTDOOR SENSOR
Yes
or
No
Required for high and low balance points
options.
RESIDUAL COOL
0
, 30, 60, 90, 120 seconds, -300 (5 minute delayed)
BALANCE POINT
Disabled
or Enabled
When enabled:
Setting used to prevent the heat pump
from heating the structure. The outdoor
temperature is below the level where the heat
pump is programmed to heat the home).
NOTE:
Balance point option will not
appear on the menu until system is
configured correctly and a outdoor
temperature sensor is installed and
enabled in the thermostat.
Low Balance Point: 25°F (-20 to 72°F)
Adjustments are in increments of 1°F (0.56°C).
Setting used to prevent the heat pump from
heating the structure. (Alert 18 - Minor -
Notification only - The outdoor temperature
is below the level where the heat pump is
programmed to heat the home).