iComfort Wi-Fi
®
7-Day Programmable Communicating Thermostat
Page 9
Table 6. System Devices > Furnace
System
Heat Pump
Furnace
Thermostat
system devices
To adjust a setting,
highlight it, then press
Edit
edit
next
back
about
resetAll
Furnace
Parameter Name
Default
Min.
Max.
Incr.
Dependency
Note or Options
Equipment Name
Dependent on model number of installed unit
Airflow Profile - Cooling
A
-
1-
-
None
A:ON:50%/30S,82%/7.5min OFF:5-%/30S
B:ON:82%/7.5min; OFF: No delays
C:ON: No delays; OFF: 45sec delay
D:No delays
Continuous Indoor Blower Airflow
nnnn CFM (See Note 3 at end of table)
De-humidification Airflow %
70
60
8-
1
None
Heating Indoor blower OFF delay
DIP SW
60
180
10
None
DIP switch setting in Non-comm.
Heating Indoor blower ON delay
30 sec
15
45
5
None
45 sec fixed in Non-Comm. IFC
Cooling Indoor blower OFF delay
0 sec
0
30
2
Outdoor Unit
present
Not used on Non Comm. IFC
Cooling indoor Blower ON Delay
2 sec
0
10
1
Outdoor Unit
present
2 sec fixed in Non-Comm. IFC
HP Indoor Blower OFF Delay
45 sec
0
60
5
Heat Pump present
Not used on Non Comm. IFC
HP Indoor Blower ON Delay
0 sec
0
30
5
Heat Pump present
Not used on Non Comm. IFC
Heating Airflow Control Type
Selections available if discharge air temperature sensor is installed (
fixed cfm and fixed discharge air temperature
).
Low Heating Airflow
Low and high heating air flow is dependent on model of indoor unit
High Heating Airflow
Gas Heat Airflow Settings
Heating Airflow Control Type
(variable capacity furnaces only)
0 – Fixed
CFM
0
1
1
DATS installed
0 (Fixed CFM)
1 (Fixed DAT)
Low Heating Airflow
(CFM @ min. heat)
DIP SW
See furnace docu
mentation (IOM or
Product Specifica
tions) for size spe
cific information
25
Heating Airflow
Control Type = 0
See furnace documentation (IOM or Product Specifica
tions) for size specific information
High Heating Airflow
(CFM @ 100% heat)
DIP SW
25
Low Heating Discharge Air
Temperature (DAT @ min heat)
(variable capacity furnaces only)
DIP SW*
5
Heating Airflow
Control Type = 1
High Heating Discharge Air
Temperature (DAT @ 100% heat)
(variable capacity furnaces only)
DIP SW*
5
* - Default DAT value is rounded to the closest number on 5 deg F resolution and limited by Minimum and Maximum value.
Cooling Airflow Settings
High Cooling Airflow
(CFM @ 100% cool)
Outdoor unit
tons
400CFM
Min
CFM
Max
CFM
25
Outdoor Unit
present
1/2 HP blower
Min
CFM
Max
CFM
25
1 HP blower
Low Cooling Airflow
(CFM @ lowest cool stage)
(See Note 1
at end of
table)
Min
CFM
Max
CFM
25
2+ stage Outdoor
Unit present
1/2 HP blower
Min
CFM
Max
CFM
25
1 HP blower