iComfort Wi-Fi
®
7-Day Programmable Communicating Thermostat
Page 11
ADJUSTING HUMIDIFICATION AND DE-HUMIDIFICATION SETTINGS WITH NON-COMMUNICATING OUTDOOR UNITS
HUMIDIFICATION SETTINGS — SYSTEM DEVICES SCREEN
System Devices
edit
about
To adjust a setting, highlight it,
then press Edit
System
resetAll
next
back
1a
1b
edit
reset
Humidification Control Mode
current value:
back
Basic
Pre-adjustment REQUIREMENTS:
1st
, the device has been
installed
(see page 5).
2nd
, you pressed
next
at the “Add or Remove...” screen (see page 5).
Configure the device as follows:
1.In the “system devices” list, use the arrows (
1a
) to highlight
System
. Press
edit
(
1b
).
2.In the “System” list, use the arrows (2
a
) to highlight
Humidification Control Mode.
The
current value defaults to Basic mode. Press
edit
(
2b
).
3.Touch one of the radio buttons (3
a
) to select the mode of humidification control; press
save
(
3b
).
(After saving, check that the current value now shows the new selection).
4.Press the
back
button to return to “Adjust a setting...” screen.
NOTE - If the defaults for the settings shown in red, you are not required to make any changes,
but you must go into the edit tool, and press
save
(
5b
). When all red text is gone, the
back
button
will appear; press it to return to the “Adjust a setting...” screen.
Display Only
Basic
Precision
Basic Dew Point Control
Precision Dew Point
Select one
Humidification Control Mode
cancel
save
3b
3a
2a
2b
System
Air Conditioner
Furnace
Thermostat
Power (120VAC) Humidifier
System
2nd Stage Differential
Staged Delay Timers
2nd Stage Delay
De-humidification Control Mo
De-humidification
Control Mode
Figure 10. Adjust a Non-Communicating Device Setting — Humidification
How Humidification Mode Works
DISPLAY, BASIC AND PRECISION
—These modes allow user
control of relative humidity between 15 and 45%. These conditions
must be met for either mode to operate:
humidification mode has been enabled, and
the unit is in HEAT mode, and
humidification demand exists (24V present at H), and
DISPLAY
mode indicates humidification is OFF.
BASIC
mode mode also requires presence of heating de
mand [Y for HP heat, or W for gas heat (W may be energized
with G de-energized)].
PRECISION
—(Available only if Wi-Fi is operational or out
door sensor is attached)
Basic Dew Point Control
adjustment mode will change the humidi
fication set point based on the outdoor temperature and a user-
defined dew point adjustment setting.
Precision Dew Point Control
adjustment mode will operate when
these conditions are met:
humidification mode has been enabled, and
the unit is in HEAT mode, and
humidification demand exists (24V present at H).
HUMIDIFICATION SETTINGS — FEATURE SCREEN
1. From the
Main Screen
, press the
right arrow
icon to go the the
Features
screen.
2. From the
Features
screen, select
system
settings.
3. Touch the button of the humidification settings you want to adjust; if it says
humidifier OFF, one touch will display a selection for ON.
4. When you touch the
set-to
button, the arrows appear, allowing you to change
to the desired humidity percentage setting.
SYSTEM SETTINGS
current indoor humidity is 50%
humidifier
is ON
de-
humidifier
MEDIUM
40
%
set to
50
%
set to
ALL CHANGES MADE ON
THIS SCREEN ARE IN
STANTLY SAVED.
9:39 am Aug 15, 2012
?
Wi-Fi
OFF
MEDIUM
HIGH
humidifier
display
is ON
(default is ON)
humidification
settings
De-humidification
settings
Figure 11. Humidification Controls
(Non-Communicating Outdoor Unit)