Service Manual JET3
Rev. 1.0
67
12. Due to some special ingredients of the cleaner, the nozzle must be washed up with
tap water at the end of the cleaning process.
Blow out the nozzle with clean air pressure (2 - 6 bar). Center the air-gun exactly in
the middle of the nozzle and blow out for several seconds. First against the nozzle
outlet and then against the nozzle entry. This process can be repeated for an
unlimited number of times.
13. To avoid that any remains of the special cleaner or water are still remaining on the
nozzle, wash up the nozzle once more with solvent and dry it with air pressure.
14. Insert the nozzle and turn forward the knurled-head-screw to the end position.
Thereby the cross bolt rotates 90 °and arrests the nozzle. Afterwards turn back the
knurled-head screw about one rotation.
Содержание JET3 up
Страница 1: ...SERVICE MANUAL ...
Страница 12: ...Service Manual JET3 12 Rev 1 0 2 4 Safety sticker Figure 1 ...
Страница 58: ...Service Manual JET3 58 Rev 1 0 7 2 Documentations for SK4 Torsional moments for SK4 ...
Страница 99: ...Service Manual JET3 Rev 1 0 99 7 3 Documentations for SK6 Torsional moments for SK6 ...
Страница 142: ...Service Manual JET3 142 Rev 1 0 ...
Страница 144: ...Service Manual JET3 144 Rev 1 0 7 4 Hydraulic 1 Hydraulic scematic ...