39
1224
1224=Stop count value
reached.
Print has stopped.
End of counter reached. Printing has been
stopped.
1300
1300=Faulty visco-
measurement.
Please check visco pump
and viscometer.
The ball has not reached the upper sensor in
the viscometer
= Sensor broken, ball hangs down, any air in
the viscometer.
Start constant bleed function for
about 10 minutes to get the air
out of the system.
Take out the viscometer and flush
it several times with solvent.
If no success exchange the
viscometer.
1301
1301=Faulty visco-
measurement.
Please check visco pump
and viscometer.
The ball does not fall (top stuck)
Dirt in the Glassss tube.
Take out the viscometer and flush
it several times with solvent.
If no success exchange the
viscometer.
1302
1302=Faulty visco-
measurement.
Please check visco pump
and viscometer.
The ball has not left the upper sensor
Dirt in the Glassss tube
Take out the viscometer and flush
it several times with solvent.
If no success exchange the
viscometer.
Содержание JET3 up
Страница 1: ...SERVICE MANUAL ...
Страница 12: ...Service Manual JET3 12 Rev 1 0 2 4 Safety sticker Figure 1 ...
Страница 58: ...Service Manual JET3 58 Rev 1 0 7 2 Documentations for SK4 Torsional moments for SK4 ...
Страница 99: ...Service Manual JET3 Rev 1 0 99 7 3 Documentations for SK6 Torsional moments for SK6 ...
Страница 142: ...Service Manual JET3 142 Rev 1 0 ...
Страница 144: ...Service Manual JET3 144 Rev 1 0 7 4 Hydraulic 1 Hydraulic scematic ...