Service Manual JET3
140
Rev. 1.0
7. Remove the flat seal.
8. Insert the new flat seal and push it correctly down.
Attention: You can insert the flat seal
only in one position!!!
If the position is not correctly,
it could be that the electrode block is not
leak-proof. Then solvent or ink can get
inside the print head and damaged them!
In this case you must change the
umbilical!
9. Fix the HV-Cable on the electrode block.
Attention:
Never mix up the red and blue cable!
Otherwise the drops will be not deflected correctly!
Fix the HV-Cables with the screws.
For this you need an
Allen key (SW 1,5 mm)!
Blue
Red
Содержание JET3 up
Страница 1: ...SERVICE MANUAL ...
Страница 12: ...Service Manual JET3 12 Rev 1 0 2 4 Safety sticker Figure 1 ...
Страница 58: ...Service Manual JET3 58 Rev 1 0 7 2 Documentations for SK4 Torsional moments for SK4 ...
Страница 99: ...Service Manual JET3 Rev 1 0 99 7 3 Documentations for SK6 Torsional moments for SK6 ...
Страница 142: ...Service Manual JET3 142 Rev 1 0 ...
Страница 144: ...Service Manual JET3 144 Rev 1 0 7 4 Hydraulic 1 Hydraulic scematic ...