17. Put the new AV Valve in the frame again and tighten the screw connection with a jaw
spanner (SW 10mm).
Caution:
To guarantee density of the hydraulic system it is absolutely necessary
to cut off the last piece of the tube which was damaged by strip the tube.
In case that the tube is too short you must change the hole tube!!!
18. Pull over the Tube on the connector.
19. Tighten the screwcap again.
20. Carry out a visual leak test, afterwards fix main pump, suction pump and the frame with
the valves on the top-hat rail, again.
To simplify the pull over
on the connector use a
wispy sandpaper.