background image

800.879.8585

www.legrand.us/wattstopper

No. 29188 – 01/20  rev. 1

© Copyright 2020 Legrand All Rights Reserved.

© Copyright 2020 Tous droits réservés Legrand.

© Copyright 2020 Legrand Todos los derechos reservados.

Wattstopper warranties its products to be free 

of defects in materials and workmanship for a 

period of five (5) years. There are no obligations 

or liabilities on the part of Wattstopper for 

consequential damages arising out of, or in 

connection with, the use or performance of this 

product or other indirect damages with respect 

to loss of property, revenue or profit, or cost of 

removal, installation or reinstallation.

Wattstopper garantit que ses produits sont 

exempts de défauts de matériaux et de fabrication 

pour une période de cinq (5) ans. Wattstopper 

ne peut être tenu responsable de tout dommage 

consécutif causé par ou lié à l’utilisation ou 

à la performance de ce produit ou tout autre 

dommage indirect lié à la perte de propriété, de 

revenus, ou de profits, ou aux coûts d’enlèvement, 

d’installation ou de réinstallation.

Wattstopper garantiza que sus productos 

están libres de defectos en materiales y mano 

de obra por un período de cinco (5) años. No 

existen obligaciones ni responsabilidades por 

parte de Wattstopper por daños consecuentes 

que se deriven o estén relacionados con el 

uso o el rendimiento de este producto u otros 

daños indirectos con respecto a la pérdida 

de propiedad, renta o ganancias, o al costo 

de extracción, instalación o reinstalación.

WARRANTY INFORMATION

INFORMATIONS RELATIVES À LA GARANTIE

INFORMACIÓN DE LA GARANTÍA

3.  Run the discovery process exactly like you would with a new installation.
4.  Since you will have a new site file, you will have to reprogram all DLM parameters for the various devices.

If replacing or resetting an LMBR in a site with more than one LMBR, you do not have to create a new site. However you will need to:

1.  Open the LMCS site file and delete the LMBR from the tree. If it was the Primary LMBR, one of the others will automatically 

become the primary.

2.  Reset ALL devices that are assigned to the network of the LMBR being replaced or reset (all other devices assigned to other 

LMBRs do NOT need to be reset).

3.  Run through the discovery process again to add the new/reset LMBR and then rediscover the devices that will connect to that 

LMBR’s network. Once the devices have been reassigned to the network, there is no need to do any room assignment since they 

already exist in the room in the project file. However, you will still need to re-pair devices by highlighting each room in the three 

and clicking the 

Wireless Device Pairing 

button.

NOTE: 

Keep in mind that if the old or reset LMBR was set to a static IP address, you will need to add a router back into the network in 

order to communicate with the new or reset LMBR, since it will be set to DHCP. Be sure to set the LMBR-650 to static IP before 

completing the process. It is not necessary to use the same static IP address as was used previously.

In order to enhance the security of our products, Legrand ships its products with all insecure ports closed and insecure protocols 

disabled. You are free to configure your device as needed, but in doing so note that you may be decreasing the security of your device 

and any information contained in the device. As you modify the device’s default settings, keep in mind how this may impact the security 

of the device and your network. In addition, you should use caution in connecting your device to the Internet, especially if you have 

altered the default security settings. If you have any questions or concerns about how your modifications of the device may affect its 

security, please contact the Legrand customer service team at 1-800-879-8585 / https://www.legrand.us/support/wattstopper.aspx

Содержание Wattstopper LMBR-650

Страница 1: ...ith the LMBR 650 see the DLM Dashboard User Guide CONNECTING LMCS 100 TO A NETWORK AND CREATING A SITE Connecting to a wireless network requires creating a site so that the network is secure and acces...

Страница 2: ...word Once logged in the lock in the Account icon will change from red to green NOTE You must be connected to the Internet the first time you log in to your account on a specific PC This will download...

Страница 3: ...the project to the site click Save To Cloud Connecting to a Network with both Wired and Wireless Rooms In the case of a network with both wired and wireless rooms the wired rooms will include an LMBC...

Страница 4: ...first log in to your cloud account and create a site or open a site previously created for the project as described in the first section of this document 2 Once this is complete click Discover on eith...

Страница 5: ...ry LMBR and the others will be considered secondary LMBRs The primary LMBR will be enabled while the others are disabled Although the first LMBR is picked as primary by default it is likely that a spe...

Страница 6: ...atic IP address return to step 2 and begin discovery again This time instead of showing up in the list as Uncommissioned the networks are displayed Select all the LMBRs and click Add After the wizard...

Страница 7: ...eturn here to configure the next one LMBR Selection NOTE It is Wattstopper best practice that the Primary LMBR be used only for communication with other LMBRs and not have any wireless devices assigne...

Страница 8: ...vices are being discovered clicking on the checkbox next to that device that has not been fully discovered will move it to the top of the list to prioritize discovery of that device So in situations i...

Страница 9: ...ected devices If you click Next that will stop the move process Click the checkbox for each device you want to add to the LMBR s network When the box turns blue it has been added 18 Once all of the se...

Страница 10: ...an LMBC 650 wireless bridge You can however have multiple room controllers in a room If you select a room controller for a room and then select an LMBC 650 while on that same room the room controller...

Страница 11: ...ou assigned to previous LMBRs will not show up in the list of devices on the Uncommissioned Device Discovery and Network Assignment dialog because they have already been moved off of the default Netwo...

Страница 12: ...ions dialog opens Leave all checkboxes selected Read Options 26 Click OK The Read Devices dialog displays the progress of the read and a log provides information When the read is complete click Close...

Страница 13: ...ices 3 If any devices are not paired and the status displays as yellow or red click Re pair The status of the controllers will turn yellow then red as they are unpaired and then pairing process starts...

Страница 14: ...tree LMBR 650 Information You can enter a Description and it will display in the tree The IP Address can be edited but if you do so it would need to be changed on the LMBR so it is recommended you do...

Страница 15: ...here It is possible to manually add wireless devices to a network with the Add Bridge and Add Device buttons However at this time there is no practical use for this function because wireless devices...

Страница 16: ...ING OR REPLACING AN LMBR 650 IN AN ALREADY COMMISSIONED NETWORK NOTE Resetting an LMBR 650 that has already been discovered using LMCS 100 software has important ramifications described below Wattstop...

Страница 17: ...ith more than one LMBR you do not have to create a new site However you will need to 1 Open the LMCS site file and delete the LMBR from the tree If it was the Primary LMBR one of the others will autom...