LEGRAND Wattstopper FSP-301 Скачать руководство пользователя страница 5

5

There is no communication with the Sensor Config App:

Perform a power cycle on the FSP-301.

ORDERING INFORMATION

Catalog #

Description

FSP-301

Digital Continuous Dimming PIR Fixture Integrated Sensor with Bluetooth

FSP-L2

360° lens, up to 44’ diameter at 8’ height

FSP-L2-S

360° lens, up to 44’ diameter at 8’ height, with shroud

FSP-L3

360° lens, up to 40’ diameter at 20’ height

FSP-L3-S

360° lens, up to 40’ diameter at 20’ height, with shroud

FSP-L7

360° lens, up to 100’ diameter at 40’ height

FSP-L7-S

360° lens, up to 100’ diameter at 40’ height, with shroud

FSP-C1

Small collar, for use with FSP-L2 and FSP-L3 lenses

FSP-C2

Large collar, for use with FSP-L7 lens

BZ-50

Power Pack: 120/277VAC, 50/60Hz, 20A ballast or incandescent

BZ-150

Power Pack: 120/277VAC, 50/60Hz, 20A ballast or incandescent, with Hold-On and Hold-Off capability

BZ-200

Power Pack: 120/277VAC, 50/60 Hz, 20A Ballast/ELV/MLV/Incandescent/LED, 16A, E-Ballast/CFL/Plug Load

BZ-250

Power Pack: 120/277VAC, 50/60 Hz, 20A, Ballast/ELV/MLV/Incandescent/LED, 16A E-Ballast/CFL/Plug Load,  

with Hold-On/Hold-Off capability

BZ-250-347

Power Pack: 120/347VAC, 50/60 Hz, 16A Ballast/ELV/MLV/Incandescent/LED/ E-Ballast/CFL, 15A Plug Load,  

with Hold-On/Hold-Off capability

Sensor is White.

FCC REGULATORY STATEMENTS

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause 

harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired 

operation.

NOTE: 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated 

in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used 

in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in 

a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own 

expense.
This device complies with FCC and IC safety levels of radio frequency (RF) exposure for Mobile devices.
This device is only authorized for use in a mobile application. At least 20 cm of separation distance between this device and the user’s 

body must be maintained at all times.
Any changes or modifications not expressly approved by The Watt Stopper Inc. could void the user’s authority to operate the equipment.

IC REGULATORY STATEMENTS

This device complies with Industry Canada licence-exempt RSS standard(s). 
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any 

interference, including interference that may cause undesired operation of the device. 

Hereby, LEGRAND declares that the radio equipment type FSP-301 is in compliance with Directive 2014/53/EU. The full text of the EU 

declaration of conformity is available at the following internet address: www.legrand.us

  This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent 

possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable 

reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the 

product was purchased. They can take this product for environmental safe recycling.

In order to enhance the security of our products, Legrand ships its products with all insecure ports closed and insecure protocols 

disabled. You are free to configure your device as needed, but in doing so note that you may be decreasing the security of your device 

and any information contained in the device. As you modify the device’s default settings, keep in mind how this may impact the security 

of the device and your network. In addition, you should use caution in connecting your device to the Internet, especially if you have 

altered the default security settings. If you have any questions or concerns about how your modifications of the device may affect its 

security, please contact the Legrand customer service team at 1-800-879-8585 / https://www.legrand.us/support/wattstopper.aspx

Содержание Wattstopper FSP-301

Страница 1: ...wer the dimming level of the lighting loads based on the ambient light and desired light level setting The FSP 301 operates at 12 32 VDC It is designed to be installed in indoor and outdoor environmen...

Страница 2: ...m the circuit breaker NOTE An optional collar can be installed in place of the tightening nut See the Ordering Information table on page 4 for details Tightening Nut or Optional Collar Tightening Nut...

Страница 3: ...ch as high low mode sensitivity time delay cut off and more With the Sensor Configuration app you can also establish and store FSP 301 parameter profiles and enable continuous dimming The Sensor Confi...

Страница 4: ...sor is not obstructed Check light level parameter to find out the amount of light that the sensor is detecting Cover the sensor lens to simulate darkness in the room If the lights come ON the setpoint...

Страница 5: ...hich case the user will be required to correct the interference at his own expense This device complies with FCC and IC safety levels of radio frequency RF exposure for Mobile devices This device is o...

Страница 6: ...ion par infrarouges passifs IRP qui r agit des changements d nergie infrarouge chaleur de corps en mouvement dans la zone de port e Une fois que le d tecteur de d tecte plus de mouvements et que le d...

Страница 7: ...REMARQUE La paroi ext rieure du luminaire ne doit pas d passer 3 18 mm 0 125 po d paisseur pour un montage et une s curit optimale du d tecteur L UTILISATION EN EXT RIEUR LAPI CE EXPOS E DE LABAGUE DU...

Страница 8: ...dant la s quence de d marrage Si le p riph rique est r initialis sa valeur par d faut ou si le mot de passe est r initialis le p riph rique recommencera la s quence de fonctionnement FSP 301CONFIGURAT...

Страница 9: ...tion nouveaux param tres pour les instructions Si les lumi res ne s ALLUMENT toujours pas appelez le 1 800 879 8585 pour obtenir une assistance technique Les lumi res ne s allument pas en mode bas la...

Страница 10: ...de provoquer des interf rences nuisibles dans un tel cas l utilisateur devra corriger les interf rences ses frais Cet appareil est conforme aux niveaux de s curit FCC et IC de l exposition aux radiofr...

Страница 11: ...301 a trav s de un orificio de 33 mm 1 30 de di metro en la parte inferior de la fixtura Los sensores usan tecnolog a de detecci n de infrarrojo pasivo PIR que reacciona a los cambios de energ a infr...

Страница 12: ...Consulte la table de informaci n de pedidos en la p gina 12 NOTA El espesor de la pared de la fixtura externo no debe ser mayor a 3 18 mm 0 125 para optimizar el montaje del sensor y la seguridad USO...

Страница 13: ...antalla de la aplicaci n Sensor Configuration muestra men s e indicaciones para guiarle a trav s de cada proceso La aplicaci n para m viles proporciona una forma sencilla de navegar por los campos de...

Страница 14: ...rovocar que las luces se mantengan apagadas Consulte la secci n de nueva configuraci n para obtener instrucciones Si las luces todav a no se encienden llame al 800 879 8585 para obtener soporte t cnic...

Страница 15: ...ambiente Para mejorar la seguridad de nuestros productos Legrand env a sus productos con todos los puertos inseguros cerrados y los protocolos inseguros deshabilitados Puede configurar su dispositivo...

Страница 16: ...ou la performance de ce produit ou tout autre dommage indirect li la perte de propri t de revenus ou de profits ou aux co ts d enl vement d installation ou de r installation Wattstopper garantiza que...

Отзывы: