5-1 SETUP & OPERATION
With the laminator on an unobstructed, level surface, perform the following checkout before
threading the machine with film.
WARNING: Make sure the power cord is clear of the underside of the machine prior to
operation to avoid overheating the cord.
MISE EN GARDE: S'assurer que le cordon d'alimentation ne passe pas sous la machine,
ce qui l'exposerait à la chaleur élevée produite par le sabot infèrieur.
ADVERTENCIA: Antes de operar la máquina, asegúrese que el cordón electrico no está
debajo de la misma, para evitar el recalentamiento del cordón.
1.
Remove any and all packing straps, rubber bands, tape, and plastic ties from the machine.
*NOTE: Save the box and packing.
2.
Make sure the heat, fan and drive switches are off before you plug in the machine. The "fan"
and "heat" switches are labeled accordingly. "0" indicates the off position. The drive switch
positions for "forward" and "reverse" are labeled. The reverse position is momentary and
will turn itself off when released. The speed control knob and dial are directly above the
forward/reverse toggle switch and the green fan switch.
3.
Plug the machine into a working outlet of at least 15 amps. Plugging in the machine does not
power on any control unless a switch has been left on. Plug in the machine and turn on the
heat. The heat indicator lamp in the heat switch will come on. It will stay on until the
machine has reached set temperature.
To adjust the heat controls:
To raise temperature:
•
Press red button once to display set point value screen
•
Press red button again to raise set point value
•
Hold red button to raise set point value rapidly
•
Wait five seconds for actual temperature to be displayed
To lower temperature:
•
Press red button once to access set point value screen
•
Press blue button to lower set point value
•
Hold blue button to decrease set point rapidly
•
Wait five seconds for actual temperature to be displayed
To switch from Fahrenheit to Celsius:
•
Hold blue button for five seconds
•
Use red button to change from degrees F to decrees C
•
Wait five second for actual temperature to display
16