User manual of ELP AC Servo
www.leadshine.com
17
4.1.3 Torque /Velocity Control Mode
Notice :
Analog input for Torque/Velocity mode is only available for ELP-RS***Z version
Noise Filter
Circuit
braker
Magenatic
contactor
L1
P+
L2
Br
1 phase
220VAC
CN1
CN2
U
PE
W
V
2
7
8
10
23
A
+
24
A
-
25
B
+
26
B
-
OCZ
36
GND
Encoder signal output
27
Z
+
28
Z
-
PE
Use twisted wire with
shield for encoder signal
output
CN3
OCB
OCA
COM_SI
A-CLR
37
29
30
39
AI1+
40
AI1-
43
AI3+
44
AI3-
+10V-~-10V
,
use twisted
wire with shield for speed
analog signal input
+10V-~-10V
,
use twisted
wire with shield for torque
analog signal input
ALM+
ALM-
18
19
BRKOFF-
21
20
1
SRV-ON
POT
4.7K
4.7K
NOT
4.7K
4.7K
12~24Vdc
32
S-RDY
33
ALM
INP
34
BRK-OFF
31
35
2
7
COM_SO
Figure 4-2 Torque/Velocity Control Mode Wiring
Note:
For driver more than 1.5kw, 3 phase is better than single phase, connect L1,L2,L3