User Manual Of ELP AC Servo
122
www.leadshine.com
Pr6.05
Name
Position 3
rd
gain valid time
Mode
P
Range
0~1000
Unit
0.1ms
Default
0
Data Type
16bit
Access
R/W
Address
060BH
Repower
-
Set up the time at which 3
rd
gain becomes valid.
When not using this parameter, set PR6.05=0, PR6.06=100
This is valid for only position control/full-closed control.
Pr6.06
Name
Position 3
rd
gain multiplication
Mode
P
Range
0~1000
Unit
100%
Default
0
Data Type
16bit
Access
R/W
Address
060DH
Repower
-
Set up the 3
rd
gain by multiplying factor of the 1
st
gain
3rd gain= 1st gain * PR6.06/100.
This function is only effective for position control. When Pr6.06 is set to non-0 value, the third gain
function will be turned on. Pr6.05 is set to specify the value of the third gain. When switching from the second
gain to the first gain, there will be a transition from the third gain. The switching time is set as Pr1.19. Take
Pr1.15=7(with or without position instruction as the first and second gain of conditional switching) as an
example to illustrate the figure below:
Command speed
:
RPM
2nd gain
Pr1.05~Pr1.09
3rd gain
1st gain
Pr1.00~Pr1.04
3rd gain
:
Position loop gain=Pr1.00 Pr6.06/100
Velocity loop gain=Pr1.01 Pr6.06/100
Pr6.05 0.1ms
8.7 Friction torque compensation
Pr6.07
Name
Torque command additional
value
Mode
P
S
T
Range
-100~100
Unit
%
Default
0
Data Type
16bit
Access
R/W
Address
060FH
Repower
-
Pr6.08
Name
Positive torque compensation
value
Mode
P
S
T