User manual of ELP AC Servo
www.leadshine.com
49
Set the center frequency of the 1st
notch filter
Notice:
the notch filter function will be invalid by setting up this parameter to “2000”.
Pr2.02
Name
1st notch width selection
Mode
P
S
T
Range
0~20
Unit
—
Default
2
Data Type
16bit
Access
R/W
Address
0205H
Repower
-
Set the width of notch at the center frequency of the 1st notch filter.
Notice:
Higher the setup, larger the notch width you can obtain. Use with default setup
in normal operation.
Pr2.03
Name
1st notch depth selection
Mode
P
S
T
Range
0~99
Unit
—
Default
0
Data Type
16bit
Access
R/W
Address
0207H
Repower
-
Set the depth of notch at the center frequency of the 1st notch filter.
Notice:
Higher the setup, shallower the notch depth and smaller the phase delay you can
obtain.
Pr2.04
Name
2nd notch frequency
Mode
P
S
T
Range
50~2000
Unit
Hz
Default
2000
Data Type
16bit
Access
R/W
Address
0209H
Repower
-
Set the center frequency of the 2nd
notch filter
Notice:
the notch filter function will be invalid by setting up this parameter to “2000”.
Pr2.05
Name
2nd notch width selection
Mode
P
S
T
Range
0~20
Unit
—
Default
2
Data Type
16bit
Access
R/W
Address
020BH
Repower
-
Set the width of notch at the center frequency of the 2nd notch filter.
Notice:
Higher the setup, larger the notch width you can obtain. Use with default setup
in normal operation.
Pr2.06
Name
2nd notch depth selection
Mode
P
S
T
Range
0~99
Unit
—
Default
0
Data Type
16bit
Access
R/W
Address
020DH
Repower
-
Set the depth of notch at the center frequency of the 2nd notch filter.
Notice:
Higher the setup, shallower the notch depth and smaller the phase delay you
can obtain.