Chapter 3 Installation
3.1 Storage and Installation Circumstance
Table 3.1 Servo Driver, Servo Motor Storage Circumstance Requirement
Item
ELP series driver
Servo motor
Temperature
-20-80
℃
-25-70
℃
Humility
Under 90%RH (free from condensation)
Under 80%RH(free from condensation)
Atmospheric
environment
Indoor(no exposure)no corrosive gas or
flammable gas, no oil or dust
Indoor(no exposure)no corrosive gas or
flammable gas, no oil or dust
Altitude
Lower than 1000m
Lower than 2500m
Vibration
Less than 0.5G (4.9m/s
2
) 10-60Hz (non-continuous working)
Protection
level
IP20(no protection)
IP54 or IP65
Table 3.2 Servo Driver, Servo Motor Installation Circumstance Requirement
Item
ELP series driver
Servo motor
Temperature
0-55
℃
-25-40
℃
Humility
Under 90%RH
(free from condensation)
Under 90%RH
(free from condensation)
Atmospheric
environment
Indoor(no exposure)no corrosive gas or
flammable gas, no oil or dust
Indoor(no exposure)no corrosive gas or
flammable gas, no oil or dust
Altitude
Lower than 1000m
Lower than 2500m
Vibration
Less than 0.5G (4.9m/s
2
) 10-60Hz (non-continuous working)
Protection
level
IP20(no protection)
IP54 or IP65
Contact [email protected] if you need more technical service .
3.2 Servo Driver Installation
Notice
Must install in control cabinet with sufficient safeguarding grade.
Must install with specified direction and intervals, and ensure good cooling condition.
Don’t install them on inflammable substance or near it to prevent fire hazard.
Install in vertical position ,and reserve enough space around the servo driver for ventilation.
The user may install the product in the mode of bottom plate installation or panel installation,
and the installation direction is perpendicular to the installation face. In order to ensure good heat
dissipation conditions, at least 10MM of installation space should be set aside in the actual
installation.
When mounting drives compactly, consider installation tolerances and leave at least 1MM
between each two drives. Use it below 75% of the actual load rate.
Here is the installation diagram: