User Manual for ELP Servo
www.leadshine.com
144
combination of IO path select signal is directly used to trigger the motion without IO CTRG signal, the path 0
is invalid. When the IO combination signal turns into a non-zero path, the path will run once triggered after IO
filtering. The timing diagram is shown below
:
Parameters
Name
Range
Default
Value
Definition
Pr8.26
IO combined
trigger mode
0~65535
0
0: invalid
,
CTRG signal trigger
1: valid after homing process finished
2: valid without homing process
Pr8.27
IO combined
filtering
0~65535
10
IO combined filtering time
Notes
:
The path 0 is invalid, so the path 0 cannot be triggered by the IO combined signal, so the IO combined
signal will trigger the motion from path 1 to path 15.
t
Path1
Path2
0x01
Ox02
0x00
Select path by IO combined signal
Path3
Ox03
IO combined
filtering time
IO combined signal trigger sequence
Notes 1
:
The path 0 is invalid, so the path 0 cannot be triggered by the IO combined signal. If users want to
trigger incremental position, the IO combined signal should be as follow:
Path X IO combined signal
—
> Path 0 IO combined signal
—
> Path Y IO combined signal, trigger
incremental position multiple times by these 3 steps.
Notes 2
:
If the IO combined trigger mode=2
(
Pr8.26=2
)
, when the drive is powered on , the motion will be
triggered while the IO combined signal select path
≠
0.
9.4.3 RS485 Communication control mode
Communication control mode can realize same function as IO operation, Can flexible modify parameters
and trigger action to run, can control more than one operation by field bus, save the wiring and good
flexibility. Communications control includes two modes: Fixed trigger mode and immediately trigger mode.
9.4.3.1 Parameters setting
Parameters
Name
Specification
Pr0.01
Control Mode Setup
Set Pr0.01=6 for Pr-Mode
Pr4.00
SI1 Input selection
Set 83 for internal Servo-Enable
Set 03 for external Servo-Enable
(
Digital SI input for Servo-Enable
)