User Manual of EL6-CAN AC Servo
www.leadshine.com
53
4
Search the homing point in negative direction, deceleration point is homing switch, homing
point is motor Z signal, the rising edge on the same side of homing switch must come before Z
signal
5
Search the homing point in negative direction, deceleration point is homing switch, homing
point is motor Z signal, the falling edge on the same side of homing switch must come before Z
signal
6
Search the homing point in positive direction, deceleration point is homing switch, homing
point is motor Z signal, the rising edge on the same side of homing switch must come before Z
signal
7
Search the homing point in positive direction, deceleration point is homing switch, homing
point is motor Z signal, the falling edge on the same side of homing switch must come before Z
signal
8
Search the homing point in positive direction, deceleration point is homing switch, homing
point is motor Z signal, the rising edge on the same side of homing switch must come before Z
signal
9
Search the homing point in positive direction, deceleration point is homing switch, homing
point is motor Z signal, the rising edge on the other side of homing switch must come before Z
signal
10
Search the homing point in positive direction, deceleration point is homing switch, homing
point is motor Z signal, the falling edge on the other side of homing switch must come before Z
signal
11
Search the homing point in negative direction, deceleration point is homing switch, homing
point is motor Z signal, the falling edge on the same side of homing switch must come before Z
signal
12
Search the homing point in negative direction, deceleration point is homing switch, homing
point is motor Z signal, the rising edge on the same side of homing switch must come before Z
signal
13
Search the homing point in negative direction, deceleration point is homing switch, homing
point is motor Z signal on the other side of homing switch, the rising edge on the other side of
homing switch must come before Z signal
14
Search the homing point in negative direction, deceleration point is homing switch, homing
point is motor Z signal on the other side of homing switch, the falling edge on the other side of
homing switch must come before Z signal
15
16
17-32
Similar with 1-14, but the deceleration point coincides with the homing point
33
Search the homing point in negative direction, homing point is motor Z signal
34
Search the homing point in positive direction, homing point is motor Z signal
35
Set the current position as homing point
Index
60FDH
Name
Status of digital input
Structure
VAR
Type
Dint 32
Access
R0
Mapping
TPDO
Mode
ALL
Range
0-ffff
Default
The bits of a 60FDh object are functionally defined as follow:
Bit31
Bit30
Bit29
Bit28
Bit27
Bit26
Bit25
Bit24
Z signal
Reserved
Reserved
Reserved
Touch
Probe 2
Touch
Probe 1
BRAKE
INP/V-COIN
/TLC
Bit23
Bit22
Bit21
Bit20
Bit19
Bit18
Bit17
Bit16
E-STOP
Reserved
Reserved
Reserved
Reserved
Reserved
SI14
SI13
Bit15
Bit14
Bit13
Bit12
Bit11
Bit10
Bit9
Bit8
SI12
SI11
SI10
SI9
SI8
SI7
SI6
SI5
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
SI4
SI3
SI2
SI1
Reserved
HOME
POT
NOT