User Manual of EL6-CAN AC Servo
www.leadshine.com
101
6.10.3 Motion Studio inertia ratio identification
This inertia ratio identification function also added in Motion Studio configuration software.
Pre-conditions
:
1
、
Servo disable. 2
、
Positive limit and negative limit invalid
Steps:
1
、
Set the Jog speed Pr6.04, and the setting should not be too large(600~1000rpm is recommend)
Set the Acc Pr6.25(50~100 ms/1000rpm is recommend)
Set the Default Inertia Ratio.
Download
these settings, then
Servo Enable
.
2
、
Click “CCW” to make motor run to CCW direction
,
click “Position 1” to save the position limit 1
Click “CW” to make motor run to CW direction
,
click “Position 2” to save the position limit 2
Click “Run” to start Inertia ratio identification.
3
、
After finishing
,
Click
“
Write
”
to save
the
Inertia ratio identification result.
6.11 Vibration Suppression
Specific resonance frequency can be obtained from PC configuration software according to waveform
monitoring, and filter frequency can be set to effectively suppress the oscillation ripple of a certain frequency
in the current instruction.