Installation and maintenance manual lba12
19
Q1
Flashing light on cover
Q2
Lights on arm
Q3
Suction cup/locking
Q4
Unhinging alarm
Q5
Green light
Q6
Red light
Relay outputs
Description
QR1
Open barrier report (NO)
QR2
Closed barrier report (NO)
QR3
Barrier unhinged/fallen arm report (NC)
QR4
Safety loop report (NO)
QR5
Fault summary report (NC)
QR6
Not assigned
Note: These are the default input/output assignments. They can change according to the type of barrier and customer.
►
Controls and viewing
o
Local controls:
o
Viewing
The screen as well as the
viewing LEDs allow you to
view the current status of
the barrier.
▪
Screen:
Here is the overview of the various possible displays on the screen from the default screen:
Control
Function
Key ▼
Local close command
(from the "Information" and "Inputs-Outputs" screens)
Key ▲
Local open command
(from the "Information" and "Inputs-Outputs" screens)
ESC key (2s)
Display of the advanced settings
ENTER key (2s)
Display of the input/output statuses
ESC + ENTER (3s)
Main menu
====Informations====
Fr: -7 Hz
Cycles: 125
BARRIER CLOSED
==== USER SELECT ===
OP
[*]
ADMIN
[ ]
====Advanced 1/2====
Cycles: 125
Unhingings: 37
Prog: PROG009714-A
"ENTER"
« ENTER »
"ESC" + "ENTER" (3s)
"ESC"
Opening/Closing
▲
Or
▼
▲
Or
▼
====Advanced 2/2====
U: 304 Vdc
Temp: 49°C
IP: 192.168.0.3
"ESC"
"ESC"
Or 60s
===Inputs-Outputs===
AI:0101 I:01101100
Q:101000 QR :001101
Opening/Closing
▲
Or
▼
Advanced settings 2/2
Status of the inputs/outputs
Identification
Default screen
Advanced settings 1/2
==== PLC MENU =====
INFORMATIONS [*]
STOP PLC [ ]
USER PARAMETERS [ ]
Main menu
Selection
of the user