Installation and maintenance manual lba12
18
o
Inputs/outputs
▪
Inputs/outputs description
Inputs/outputs
Terminal
block(s)
Terminals
Description
Digital inputs 24Vdc
I1 to I8
- ; + ; Ix
24Vdc All or Nothing inputs for the barrier controls
Digital inputs 0-10V (or digital 24Vdc)
AI1 to AI4
- ; + ; AIx
Analogue Inputs 0-10V which can be configured as 24Vdc
All or Nothing for connecting position sensors
Transistor outputs 24Vdc
Q1 to Q6
- ; Qx
24Vdc All or Nothing outputs for controlling the various
accessories of the barrier (0.75A per output; max.: 40W
total).
Relay outputs
QR1 to QR6
QRx
Dry contact All or Nothing outputs for information reports
(contact: 10A 250Vac)
0-10V analogue output
AQ
- ; AQ
0-10V analogue output for the controlling of an analogue
accessory
Encoder
Encod
Encod
Encoder input for the connecting of an absolute angular
position sensor
Motor connection
Terminal
block(s)
Terminals
Description
Motor phases
Motor
U; V; W; GND
3-phase power supply of the motor and the ground (Max.
power: 0.55kW)
Brake relay
R Br
R Br
Dry contact relay output for the controlling of the brake of
the motor (if needed)
Power supply
Terminal
block(s)
Terminals
Description
230V AC power supply
230Vac
L; N; GND
General power supply of the control board
Additional 24Vdc input
N/A
N/A
24Vdc input available if needed, in the event the max.
power (40W) is exceeded on the transistor outputs
Communication
Description
Ethernet
TCP/IP Modbus port.
MBus RTU
RTU RS485 Modbus port.
Serial link
Allows you to programme the electronic board
Update / backup
Description
SD Card
Location of the SD card for automatic backup of the programme.
Also allows for the insertion of a SD card to update or back up the PLC programme or the internal
firmware of the board
▪
Default assignment of the inputs/outputs
I1
Open command (NO)
I2
Close command (NO)
I3
Magnetic safety loop (NC)
I4
Safety infrared cell (or ultrasound detection) (NC) no. 1
I5
Safety infrared cell (or ultrasound detection) (NC) no. 2
I6
Free opening magnetic loop (NO)
I7
Automatic/Manuel mode (1: Auto; 0: Man)
I8
Unhinging sensor (or fallen arm) (NC)
Analogue/digital inputs
Description
AI1
Opening end-of-travel sensor (NO)
AI2
Opening slowdown sensor (NO)
AI3
Closing slowdown sensor (NO) or crank end-of-travel (irreversible barriers)
AI4
Closing end-of-travel sensor (NO)
Transistor outputs
Description