Installation and maintenance manual lba12
21
Note: The screen display automatically returns to the "Information" screen after 60s if no button is pressed.
Details on the main menu will be provided hereinafter.
▪
LEDs:
The LEDs also make it possible to view the status of the inputs/outputs as well as the useful voltages:
•
LED on: input/output active (1)
•
LED off: input/output inactive (0)
Note: Contrary to the screen for viewing the status of the inputs/outputs, here, the analogue inputs AI1 to AI4 are not viewed as
they cannot be represented by LEDs.
►
Messages and safety component activation
o
Status messages of the barrier:
Here are the various status messages of the barrier (last line on the information screen):
Message
Meaning
« BARRIER OPEN »
The barrier is open and the automatic closing after the time delay or auto mode
are not activated
« BARRIER OPEN 15S »
The barrier is open and the barrier will close automatically at the end of a
countdown timer (Automatic closing after time delay and auto mode activated)
Note: if the countdown timer remains at 15s, this means that an order to open
and/or a safety component is activated
« BARRIER CLOSED »
The barrier is closed
« OPENNING »
The barrier is in the process of opening
« CLOSING »
The barrier is in the process of closing
« DETECTION LOOP »
A vehicle is present on the safety loop.
Closing the barrier is impossible.
« DETECTION CELL »
A vehicle is present in front of the infrared or ultrasound cell(s).
Closing the barrier is impossible.
« BARRIER UNHINGED »
The barrier is unhinged.
The closing of the barrier is impossible if the option "Automatic rehinging"
is activated.
« CRANK MISSING »
The crank is not in its housing.
Controlling the barrier is impossible. The motor is cut off.
o
Messages for safety activation of the barrier:
Here are the various messages for safety activation of the barrier:
Message
Meaning
"Operation time exceeded"
The time for opening or closing the barrier has exceeded the manoeuvring time
(by default: 30s).
Motor control is cut off. The barrier has to be reset.
"Motor in fault
Error code: XXX"
The motor is in fault.
The error code is indicated.
Error codes:
0:
No error
106:
Winding calculation error when powering up (motor disconnected, short-
circuit on the phases, incorrect configuration of the motor, etc.)
107:
Overheating of the IGBT module
Other:
Contact After-Sales Service
I1 to I4
I5 to I8
Q1 to Q6
QR1 to QR6
24V
5V
3
.3
V