![Lawo AG zirkon Скачать руководство пользователя страница 62](http://html2.mh-extra.com/html/lawo-ag/zirkon/zirkon_configuration-manual_3955881062.webp)
Configuration with the PC
Connect/Routing
62/ 148
V 1.2
zirkon Configuration Manual
This way you can freely assign the controls for control room
monitoring, headset or studio monitoring volume.
This way you can set also the controls for the output level
in the status “DIM”. Here you can assign different controls
for the two separate outputs.
Standard value for the Dim Level works similar to the
Default level. It is used for signal processing if no control
is assigned to the output level diminuition.
7.
Enter here the value for the “Dim Level”!
All the following parameters are control inputs.
Out.L Mute and Out.R Mute switch off the ouputs Left or
Right.
8.
Assign a button to this function by a double-click!
With Mono the two input signals are mixed with an
diminuition of 3dB at the outputs.
Phase rotates the right input signal by 180 degrees.
SIDE routes the right input signal to the left output and
vice versa.
In.L Dim and In.R Dim diminuate the left or right output
signal.
All functions are active as long as the control signal is a
logical “one”.
Connect/Routing
Apart from assignment of a “Default Audio” in the
configuration of the output hardware you can carry out
connects between audio inputs and outputs. This
facilitates
the
programming
of
e.
g.
monitoring
functionalities or simple matrix applications.
1.
Click with the right mouse-key on the sub-directory
“Connect”!
The displayed window opens!
2.
Assign the crosspoint to a group!
3.
Confirm with “OK”!