Commissioning
Air conditioning and grounding of the zirkon
zirkon Configuration Manual
V 1.2
19/ 148
Error messages
Error messages are displayed via collective alarm contact.
For the transfer the system unit is fitted with a 15-pin
DSub- and a BNC connector.
Depending on the configuration the power consumption
of the system unit adds up to 70W and a maximum of
200W (with redundant PSU).
The system unit is supplied with power via the top cold-
device connector.
Operator protection is guaranteed as the system unit is
connected via the cold-device plugs with the ground of
the power supply system.
Attention!
Establish an additional ground for safety. You can fix it
directly to the mounting frame. Use the M4 screw thread
at the housing rear!
Optionally you can install an additional PSU. To this end,
the system unit offers two inputs for mains voltage. We
recommend to supply the two inputs by separate circuits.