System page and error messages
Check connections – when something went wrong!
102/ 148
V 1.2
zirkon Configuration Manual
I changed the setup and receive no answer on my “ping”
command.
Lights up the RUN-LED?
Operate the reset button at the front plate. Wait
until the RUN LED lights up cyclically which means
the system is started-up.
Is an IP address assigned to the PC within the same
number range?
Change the IP address of your PC so that they lie
within the same number range as the masterboard.
Acquire the required information via internet (e. g.
http://www.microsoft.com,
http://www.leo.org/information/computer/auskunf
t.de.html) abgerufen werden.
Do you have entered the address according to the format
192.168.0.2(address) -> 192.168.000.002(input)?
Enter the address in the requested format. Carry
out a “ping” command again.
I have forgotten the TCP/IP address.
Draw the masterboard out of the system unit.
Unscrew the plug-in module
Plug the top jumper:
Replug the masterboard into the system unit.
Carry out the “ping” command again with the
settings ex works. Ex works settings (IP address
192.168.101.240 Subnet mask 255.255.255.0).
Load your setup again.