Figure 3-27
EXAMPLE OF NEGATIVE SPIN SPEED VALUE
PROCESSING TIP:
An agitation type program is possible when using both
positive and negative spin speeds. The below example is meant to show how
agitation programming is possible. Use the Cpm field to enter an agitation rate
(15, 30 or 60 cpm) or the user can build their own program and rate.
EXAMPLE OF AN AGITATION PROGRAMMING
Step Time
99 59.9
Speed
0-6,000
Valves
X=ON
Accel
Comment
Min
Sec
1
00.5 100
1 2 3 4 5 6 7
8
1000
2
00.5
-100
1 2 3 4 5 6 7
8
1000
3
00.5
100
1 2 3 4 5 6 7
8
1000
4
00.5
-100
1 2 3 4 5 6 7
8
1000
5
00.5
100
1 2 3 4 5 6 7
8
1000
6
00.5
-100
1 2 3 4 5 6 7
8
1000
7
00.5
100
1 2 3 4 5 6 7
8
1000
8
00.5
-100
1 2 3 4 5 6 7
8
1000
9
00.5
100
1 2 3 4 5 6 7
8
1000
10
00.5
-100
1 2 3 4 5 6 7
8
1000