Piping / Connections

Inlet connection is 3/8” N.P.T.
There  should  be  a  minimum  6-inch  (15.24  cm)  clearance

between the back guard and the first bend in the gas piping

for ease of servicing.  It is recommended that a gas shutoff

valve be provided to the gas supply line of each dryer for

ease in servicing.
The  size  of  the  main  gas  supply  line  (header)  will  vary

depending on the distance this line travels from the gas meter

or, in the case of L.P. gas, the supply tank, other gas-operated

appliances  on  the  same  line,  etc.    Specific  information

regarding supply line size should be determined by the gas

supplier.

NOTE: 

Undersized gas supply piping can create a low or

inconsistent pressure, which will result in erratic operation

of the burner ignition system.

TYPICAL NATURAL GAS INSTALLATION

TYPICAL L.P. GAS INSTALLATION

Heat Input / Gas Consumption/Orifice (Injector) Data

Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.

** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

Consistent gas pressure is essential at all gas connections.

It is recommended that a 3/4-inch (19.05 mm) pipe gas loop

be installed in the supply line servicing a bank of dryers.  An

in-line pressure regulator must be installed in the gas supply

line (header) if the (natural) gas pressure exceeds 13.0 in

WC (32.34 mb) pressure.
A plugged tap, accessible for a pressure gauge connection,

must  be  installed  in  the  main  gas  supply  line  immediately

upstream of the dryers.

IMPORTANT: 

Pipe joint compounds that resist the action

of natural, L.P., and butane gases must be used.
Test all connections for leaks by brushing on a soapy

water solution (liquid detergent works well).

!

 WARNING

Never test for leaks with a flame!!!

Converting from One Family

of Gas to Another _____________________

!

 WARNING

This appliance must only be operated with the gas
type  indicated  on  the  dryer’s  data  plate.    If  the
appliance  is  converted  (gas  type  changed),  a  data
plate  amendment  must  be  obtained  from  the
manufacturer  (dryer’s  serial  number  is  required  to
purchase a conversion kit).

IMPORTANT: 

Any burner changes or conversions must be

made by a qualified professional.

Conversion from Natural Gas

to Propane or Butane Gas

The following conversion allows the dryer to be operated with

either  propane,  butane,  or  LPG.   The  use  of  gas  valve  kit

(P/N 140414) disables the internal regulator of the gas valve.

Therefore,  the  gas  supply  is  ungoverned  and  an  external

regulator  must  be  provided  at  the  source  of  the  supply

(example L.P. tank) or the gas supply line to the dryer.  The

type of L.P. kit supplied will depend on the country the dryer

is installed in.

Gas Specifications for Non-CE and Non-AGA Approved Dryers

**

Gas

Type

Nominal

Heating Value

Supply

Pressure

Gross

Heat Input

Orifice Size

Orifice

(Injector)
Quantity

Burner

Pressure

B tu /ft

3

in WC

Btu/hr

kW

DMS

mm

in WC

 Natural

1,000

6.0-12.0

26,000

7.6

40

2.489

1

3.0

 

*

Liquid Propane

2,500

11.0

26,000

7.6

53

1.511

1

10.5

Содержание DAWF0 SERIES

Страница 1: ...ass by itself Part No 112819 1 Laundrylux 461 Doughty Boulevard Inwood NY 11096 0338 www laundrylux com Service 516 371 0700 Parts 516 271 2000 DAWF0 and DAWS0 SERIES DRYERS D R Y E R I N S T A L L AT I O N M A N U A L ...

Страница 2: ...nical instructions which will provide the necessary information concerning the modification of the appliance to the condition of use for the country In accordance with EN ISO 3166 1 the names of countries shall be represented by the following codes GB United Kingdom IE Ireland Retain This Manual in a Safe Place for Future Reference This product embodies advanced concepts in engineering design and ...

Страница 3: ...sachusetts If using a ball valve it shall be a T handle type A flexible gas connector when used must not exceed 3 feet WARNING Children should not be allowed to play on or near the dryer s Children should be supervised if near dryer s in operation Under no circumstances should the dryer door switch es lint door switch es or heat safety circuit s ever be disabled Do not modify this appliance The dr...

Страница 4: ...cooking oil constitute a fire hazard and should not be placed in a tumble dryer Do not dry mop heads Contamination by wax or flammable solvents will create a fire hazard WARNING Do not use heat for drying articles that contain plastic foam sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be ...

Страница 5: ...___________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed fro...

Страница 6: ...ø 2w 60 Hz APPROXIMATE NET WEIGHT 176 lb 79 83 kg APPROXIMATE SHIPPING WEIGHT 198 lb 89 81 kg AIRFLOW 220 cfm 6 23 cmm HEAT INPUT 26 000 Btu hr 6 550 kcal hr EXHAUST CONNECTION DIAMETER 4 10 16 cm NATURAL GAS SUPPLY PRESSURE 6 12 in WC NATURAL GAS MANIFOLD PRESSURE 3 in WC L P SUPPLY PRESSURE 11 in WC L P MANIFOLD PRESSURE 10 5 in WC INLET PIPE CONNECTION 3 8 M N P T VOLTAGE AVAILABLE 208 240V 1ø ...

Страница 7: ... Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation TopControl ...

Страница 8: ...8 112819 1 Specifications _____________________________________________________________________ Bottom Control Stackable ...

Страница 9: ...st Requirements section The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combusti...

Страница 10: ...ng out of the top of the washer There are two Feed both harnesses into the bottom of the dryer using the rear cutout hole Do not feed through the coin access funnel hole See diagram Non metered card and non coin installations do not need to interconnect harnesses between the washer and dryer Align the dryer mounting holes over the threaded adapter plate holes The front of the washer and dryer will...

Страница 11: ... of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts overlap the duct being connected All ductwork joints must be taped to prevent moisture and lint from escaping into the building Back draft dampers must be installed in all commonly d...

Страница 12: ...e ductwork must be increased Vertical Venting When vertical dryer venting is used the length of the ductwork from the dryer to the outside exhaust outlet must not exceed 12 feet 3 66 meters The diameter of this ductwork must be 4 inches 10 16 cm Including tumbler dryer elbow connections or elbows used for outside protection from the weather no more than 3 elbows should be used in the exhaust duct ...

Страница 13: ...just the autotransformer located near the burner assembly To adjust the autotransformer wiring place the red wire on the appropriate tap HIGH MED LOW of the autotransformer For additional wiring details refer to the electrical diagram located on the inside of the control panel TERM LINE VOLTAGE 60 Hz HIGH 283 249 MED 260 230 LOW 236 208 7 18 12 Electric Models Only All electrically heated dryers m...

Страница 14: ... the manufacturer IMPORTANT If connection to this appliance is made with a flexible hose it must be suitable for the appliance category in accordance with national installation regulations of the country of destination and if in doubt the installer must contact the supplier The manufacturer of this appliance does not recommend the use of flexible gas supply line hose An external gas supply shutoff...

Страница 15: ...essible for a pressure gauge connection must be installed in the main gas supply line immediately upstream of the dryers IMPORTANT Pipe joint compounds that resist the action of natural L P and butane gases must be used Test all connections for leaks by brushing on a soapy water solution liquid detergent works well WARNING Never test for leaks with a flame Converting from One Family of Gas to Anot...

Страница 16: ... and affix this label as close as possible to the dryer s existing dryer rating data label plate Affix L P Conversion Rating Label Addendum P N 114090 as close as possible to the dryer s existing dryer rating data label plate Open all shutoff valves reconnect electrical power to the dryer and test for leaks IMPORTANT Never test for leaks with an open flame Use a soapy water solution or product int...

Страница 17: ...onversions done improperly can result in a fire or explosion Gas Pressure Testing For proper operation the gas pressure must be correct consistent and maintained at the gas pressure rates shown on page 15 Provisions are made at the gas valve for taking gas pressure readings There are two types of devices used to measure gas pressure They are the spring mechanical type gauge and the manometer The u...

Страница 18: ...elections Each microprocessor controller computer has been preprogrammed by the factory with the most commonly used parameter program selections If computer program changes are required refer to the computer programming manual which was shipped with the dryer Preoperational Instructions __________ IMPORTANT For more detailed information regarding the microprocessor controller computer refer to the...

Страница 19: ...e After Each Load Clean the lint screen after each load A clogged lint screen will cause poor dryer performance The lint door is located just below the loading door of the dryer Open the lint door brush the lint off the lint screen and remove the lint Inspect lint screen and replace if damaged Weekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area WA...

Страница 20: ...___________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ______...

Страница 21: ..._________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________...

Страница 22: ...Part No 112819 ...

Отзывы: