Installation Procedures ______________

Installation should be performed by competent professional

in accordance with local, state, and country codes.  In the

absence  of  these  codes,  the  installation  must  conform  to

applicable American  National  Standards: ANSI  Z223.1-

LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA

NO.  70-LATEST  EDITION  (National  Electrical  Code)  or  in

Canada, the installation must conform to applicable Canadian

Standards:  CAN/CGA-B149.1-M91  (Natural  Gas)  or  CAN/

CGA-B149.2-M91  (L.P.  Gas)  or  LATEST  EDITION  (for

General  Installation  and  Gas  Plumbing)  or  Canadian

Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST

EDITION (for Electrical Connections).

Location Requirements ______________

Before installing the dryer, be sure the location conforms to

local, state, and country codes.  In the absence of such codes

or ordinances the location must conform with the National

Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada,

the  installation  must  conform  to  applicable  Canadian

Standards:  CAN/CGA-B149.1-M91  (Natural  Gas)  or  CAN/

CGA-B149.2-M91  (L.P.  Gas)  or  LATEST  EDITION  (for

General Installation and Gas Plumbing).
The dryer must be installed on a sound level floor capable of

supporting its weight.  Carpeting must be removed from the

floor area that the dryer is to rest on.
The dryer must not be installed or stored in an area where it

will be exposed to water and/or weather.
Dryers  installed  in  residential  garages  must  be  elevated

18-inches (45.72 cm) above the floor.
Provisions for adequate air supply must be provided as noted

in  this  manual  (refer  to  Fresh Air  Supply  Requirements

section).
Clearance  provisions  must  be  made  from  combustible

construction as noted in this manual (refer to Dryer Enclosure

Requirements section).
Provisions  must  be  made  for  adequate  clearances  for

servicing and for operation as noted in this manual (refer to

Dryer Enclosure Requirements section).
The  dryer  must  be  installed  with  a  proper  exhaust  duct

connection to the outside as noted in this manual (refer to

Exhaust Requirements section).
The dryer must be located in an area where correct exhaust

venting can be achieved as noted in this manual (refer to

Exhaust Requirements section).

IMPORTANT: 

The dryer should be located where a

minimum amount of exhaust ducting will be necessary.

The dryer must be installed with adequate clearance for air

openings into the combustion chamber.

CAUTION: This dryer produces combustible lint and
must be exhausted to the outdoors.  Every 6 months,
inspect  the  exhaust  ducting  and  remove  any  lint
buildup.

IMPORTANT: 

The dryer must be installed in a location/

environment, which the ambient temperature remains

between 40° F (4.44° C) and 130° F (54.44° C).

Unpacking / Setting Up ________________

Remove protective shipping material (i.e., plastic wrap and

optional shipping box) from the dryer.

IMPORTANT: 

Dryer must be transported and handled in an

upright position at all times.

The dryer can be moved to its final location while still attached

to the skid or with the skid removed.
With  the  skid  removed,  use  caution  and  assure  all  four

leveling legs on stand-alone models are fully retracted, if the

dryer is to be slid into its final position.

Leveling Dryer

Stand-alone  model  dryers  are  equipped  with  four  leveling

legs, one at each corner of the assembling the stacking dryer

base.  For optimum performance the dryer should be level

front-to-back and side-to-side.

Dryer Enclosure Requirements _______

Commercial Type II

Bulkheads and partitions should be made of noncombustible

material.

NOTE: 

Allowances must be made for opening the control

door.

A

The requirement to allow the door to open completely is

25 1/2-inches (64.77 cm).

B

A minimum overhead clearance of 6-inches (15.24 cm)

is required.

C Dryer  should  be  positioned  a  minimum  of  12-inches

(30.48 cm) away from the nearest obstruction.  24-inches

(60.96  cm)  is  recommended  for  ease  of  installation,

maintenance, and service.

D 1/16” (1.5875 mm) minimum is required.
E

Flooring should be level and below dryer cabinet for ease

of removing panels during maintenance.

F

Dryers may be positioned sidewall to sidewall, however

a 1/16” (1.5875 mm) minimum allowance must be made

for the opening and closing of the control door, along

with the removal of panels during maintenance.

Содержание DAWF0 SERIES

Страница 1: ...ass by itself Part No 112819 1 Laundrylux 461 Doughty Boulevard Inwood NY 11096 0338 www laundrylux com Service 516 371 0700 Parts 516 271 2000 DAWF0 and DAWS0 SERIES DRYERS D R Y E R I N S T A L L AT I O N M A N U A L ...

Страница 2: ...nical instructions which will provide the necessary information concerning the modification of the appliance to the condition of use for the country In accordance with EN ISO 3166 1 the names of countries shall be represented by the following codes GB United Kingdom IE Ireland Retain This Manual in a Safe Place for Future Reference This product embodies advanced concepts in engineering design and ...

Страница 3: ...sachusetts If using a ball valve it shall be a T handle type A flexible gas connector when used must not exceed 3 feet WARNING Children should not be allowed to play on or near the dryer s Children should be supervised if near dryer s in operation Under no circumstances should the dryer door switch es lint door switch es or heat safety circuit s ever be disabled Do not modify this appliance The dr...

Страница 4: ...cooking oil constitute a fire hazard and should not be placed in a tumble dryer Do not dry mop heads Contamination by wax or flammable solvents will create a fire hazard WARNING Do not use heat for drying articles that contain plastic foam sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be ...

Страница 5: ...___________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed fro...

Страница 6: ...ø 2w 60 Hz APPROXIMATE NET WEIGHT 176 lb 79 83 kg APPROXIMATE SHIPPING WEIGHT 198 lb 89 81 kg AIRFLOW 220 cfm 6 23 cmm HEAT INPUT 26 000 Btu hr 6 550 kcal hr EXHAUST CONNECTION DIAMETER 4 10 16 cm NATURAL GAS SUPPLY PRESSURE 6 12 in WC NATURAL GAS MANIFOLD PRESSURE 3 in WC L P SUPPLY PRESSURE 11 in WC L P MANIFOLD PRESSURE 10 5 in WC INLET PIPE CONNECTION 3 8 M N P T VOLTAGE AVAILABLE 208 240V 1ø ...

Страница 7: ... Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation TopControl ...

Страница 8: ...8 112819 1 Specifications _____________________________________________________________________ Bottom Control Stackable ...

Страница 9: ...st Requirements section The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combusti...

Страница 10: ...ng out of the top of the washer There are two Feed both harnesses into the bottom of the dryer using the rear cutout hole Do not feed through the coin access funnel hole See diagram Non metered card and non coin installations do not need to interconnect harnesses between the washer and dryer Align the dryer mounting holes over the threaded adapter plate holes The front of the washer and dryer will...

Страница 11: ... of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts overlap the duct being connected All ductwork joints must be taped to prevent moisture and lint from escaping into the building Back draft dampers must be installed in all commonly d...

Страница 12: ...e ductwork must be increased Vertical Venting When vertical dryer venting is used the length of the ductwork from the dryer to the outside exhaust outlet must not exceed 12 feet 3 66 meters The diameter of this ductwork must be 4 inches 10 16 cm Including tumbler dryer elbow connections or elbows used for outside protection from the weather no more than 3 elbows should be used in the exhaust duct ...

Страница 13: ...just the autotransformer located near the burner assembly To adjust the autotransformer wiring place the red wire on the appropriate tap HIGH MED LOW of the autotransformer For additional wiring details refer to the electrical diagram located on the inside of the control panel TERM LINE VOLTAGE 60 Hz HIGH 283 249 MED 260 230 LOW 236 208 7 18 12 Electric Models Only All electrically heated dryers m...

Страница 14: ... the manufacturer IMPORTANT If connection to this appliance is made with a flexible hose it must be suitable for the appliance category in accordance with national installation regulations of the country of destination and if in doubt the installer must contact the supplier The manufacturer of this appliance does not recommend the use of flexible gas supply line hose An external gas supply shutoff...

Страница 15: ...essible for a pressure gauge connection must be installed in the main gas supply line immediately upstream of the dryers IMPORTANT Pipe joint compounds that resist the action of natural L P and butane gases must be used Test all connections for leaks by brushing on a soapy water solution liquid detergent works well WARNING Never test for leaks with a flame Converting from One Family of Gas to Anot...

Страница 16: ... and affix this label as close as possible to the dryer s existing dryer rating data label plate Affix L P Conversion Rating Label Addendum P N 114090 as close as possible to the dryer s existing dryer rating data label plate Open all shutoff valves reconnect electrical power to the dryer and test for leaks IMPORTANT Never test for leaks with an open flame Use a soapy water solution or product int...

Страница 17: ...onversions done improperly can result in a fire or explosion Gas Pressure Testing For proper operation the gas pressure must be correct consistent and maintained at the gas pressure rates shown on page 15 Provisions are made at the gas valve for taking gas pressure readings There are two types of devices used to measure gas pressure They are the spring mechanical type gauge and the manometer The u...

Страница 18: ...elections Each microprocessor controller computer has been preprogrammed by the factory with the most commonly used parameter program selections If computer program changes are required refer to the computer programming manual which was shipped with the dryer Preoperational Instructions __________ IMPORTANT For more detailed information regarding the microprocessor controller computer refer to the...

Страница 19: ...e After Each Load Clean the lint screen after each load A clogged lint screen will cause poor dryer performance The lint door is located just below the loading door of the dryer Open the lint door brush the lint off the lint screen and remove the lint Inspect lint screen and replace if damaged Weekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area WA...

Страница 20: ...___________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ______...

Страница 21: ..._________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________...

Страница 22: ...Part No 112819 ...

Отзывы: