Domestic Type I

EXAMPLE: Two unrestricted openings measuring 6-inches

by 10-inches (15.24 cm by 25.4 cm) are acceptable.
If a closet door is installed: unobstructed air openings are

required.    The  air  openings  shall  be  located  3-inches

(7.62 cm) from the lower opening (above floor level) and upper

opening (below ceiling).  The total free area of the air openings

in the door shall not be less than 130 inch

2

 (838.708 cm

2

).

Louvered doors with equivalent air openings are acceptable.
No other fuel-burning appliance shall be installed in the same

closet as the dryer.

Stacked Dryer-Washer Installation __

DAWS0  Series  Crossover  dryers  are  mounted  on  top  of

Crossover washers.  A mounting kit consisting of an adapter

plate and bolts and washers is included with each DAWS0

series dryer to allow hard mounting of the dryer on top of the

washer.  Mounting the dryer will require access to the back

of  the  dryer  after  placing  it  on  the  washer   All  installation

requirements for both machines must be observed.
If  not  already  done,  set  up,  level,  program,  and  run  the

Crossover washer to confirm desired operation.

A = 6-inches (15.24 cm)
B = 10-inches (25.4 cm)

Remove the Crossover washer top cover and replace with

the mounting adapter plate supplied with the dryer.  Resecure

the adapter plate using the two ST3.5 screws originally used

to secure the washer cover.  Do NOT use excessive force to

align the plate.  Adjusting with a hammer can damage the

washer’s mounting clips compromising structural integrity of

the integrated pair.  On the base of the dryer, knock out four

mounting bolt holes.  For metered (coin) installations knock

out one washer harness hole.
To install  the  mounting  bolts  you  will  need  to  remove  the

machine  service  access  grill  cover  located  on  lower  back

side of the dryer.  Open the front control panel by unlocking

and removing the two mounting screws.  The control panel

rotates forward and down.  On metered models, remove the

coin funnel, which is secured in place with a screw and a tab.
For metered (coin) installations, place the dryer on the washer

askew so you can still see the washer coin harnesses coming

out  of  the  top  of  the  washer.    There  are  two.    Feed  both

harnesses into the bottom of the dryer using the rear cutout

hole.  Do not feed through the coin access funnel hole.  See

diagram.  Non-metered (card and non-coin) installations do

not need to interconnect harnesses between the washer and

dryer.
Align  the  dryer  mounting  holes  over  the  threaded  adapter

plate holes.  The front of the washer and dryer will be flush.

Start the two bolts (with lock washers), which are accessible

from  the  front  of  the  machine.    Start  the  two  rear  bolts

accessible  via  the  rear  service  panel.    On  metered

installations make sure the washer’s coin harnesses are not

pinched  between  the  machines  and  tighten  all  four  bolts.

Secure rear service panel.
On metered installations connect the right side coin meter to

the Crossover washer red (0.25¢) harness.  The white $1.00

harness is unused.  Replace and secure coin funnel.  Route

the washer harness on the right of and at the base of the

coin funnel.  This will prevent the harness from moving during

wash  extra

ct

  and  blocking  quarters  from  dropping  into 

the

coin 

vault in 

the 

washer. Make sure dryer coin meter harness

and 

unused Crossover white $1.00 harness are secured so

they 

do not block the coin drop pathway.

Resecure front control panel.

Fresh Air Supply Requirements ______

When the dryer is operating, it draws in room air, heats it,

passes this air through the tumbler, and exhausts it out of

the  building.    Therefore,  the  room  air  must  be  continually

replenished  from  the  outdoors.    If  the  make-up  air  is

inadequate, drying time and drying efficiency will be adversely

affected.  Ignition problems may result, as well as premature

motor failure from overheating.  The dryer must be installed

with  provisions  for  adequate  combustion  and  make-up  air

supply.
Air supply (make-up air) must be given careful consideration

to  ensure  proper  performance  of  each  dryer.    Fresh  air

ventilation openings shall not be blocked and/or sealed.  As

a general rule, an unrestricted air entrance from the outdoors

of  26  inch

2

  (168  cm

2

)  for  each  dryer.    (Based  on  1  inch

2

[6.5 cm

2

] per 1,000 Btu [252 kcal].)

It is not necessary to have a separate make-up air opening

for  each  dryer.    Common  make-up  air  openings  are

acceptable.  However, they must be set up in such a manner

that the make-up air is distributed equally to all the dryers.

Содержание DAWF0 SERIES

Страница 1: ...ass by itself Part No 112819 1 Laundrylux 461 Doughty Boulevard Inwood NY 11096 0338 www laundrylux com Service 516 371 0700 Parts 516 271 2000 DAWF0 and DAWS0 SERIES DRYERS D R Y E R I N S T A L L AT I O N M A N U A L ...

Страница 2: ...nical instructions which will provide the necessary information concerning the modification of the appliance to the condition of use for the country In accordance with EN ISO 3166 1 the names of countries shall be represented by the following codes GB United Kingdom IE Ireland Retain This Manual in a Safe Place for Future Reference This product embodies advanced concepts in engineering design and ...

Страница 3: ...sachusetts If using a ball valve it shall be a T handle type A flexible gas connector when used must not exceed 3 feet WARNING Children should not be allowed to play on or near the dryer s Children should be supervised if near dryer s in operation Under no circumstances should the dryer door switch es lint door switch es or heat safety circuit s ever be disabled Do not modify this appliance The dr...

Страница 4: ...cooking oil constitute a fire hazard and should not be placed in a tumble dryer Do not dry mop heads Contamination by wax or flammable solvents will create a fire hazard WARNING Do not use heat for drying articles that contain plastic foam sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be ...

Страница 5: ...___________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed fro...

Страница 6: ...ø 2w 60 Hz APPROXIMATE NET WEIGHT 176 lb 79 83 kg APPROXIMATE SHIPPING WEIGHT 198 lb 89 81 kg AIRFLOW 220 cfm 6 23 cmm HEAT INPUT 26 000 Btu hr 6 550 kcal hr EXHAUST CONNECTION DIAMETER 4 10 16 cm NATURAL GAS SUPPLY PRESSURE 6 12 in WC NATURAL GAS MANIFOLD PRESSURE 3 in WC L P SUPPLY PRESSURE 11 in WC L P MANIFOLD PRESSURE 10 5 in WC INLET PIPE CONNECTION 3 8 M N P T VOLTAGE AVAILABLE 208 240V 1ø ...

Страница 7: ... Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation TopControl ...

Страница 8: ...8 112819 1 Specifications _____________________________________________________________________ Bottom Control Stackable ...

Страница 9: ...st Requirements section The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combusti...

Страница 10: ...ng out of the top of the washer There are two Feed both harnesses into the bottom of the dryer using the rear cutout hole Do not feed through the coin access funnel hole See diagram Non metered card and non coin installations do not need to interconnect harnesses between the washer and dryer Align the dryer mounting holes over the threaded adapter plate holes The front of the washer and dryer will...

Страница 11: ... of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts overlap the duct being connected All ductwork joints must be taped to prevent moisture and lint from escaping into the building Back draft dampers must be installed in all commonly d...

Страница 12: ...e ductwork must be increased Vertical Venting When vertical dryer venting is used the length of the ductwork from the dryer to the outside exhaust outlet must not exceed 12 feet 3 66 meters The diameter of this ductwork must be 4 inches 10 16 cm Including tumbler dryer elbow connections or elbows used for outside protection from the weather no more than 3 elbows should be used in the exhaust duct ...

Страница 13: ...just the autotransformer located near the burner assembly To adjust the autotransformer wiring place the red wire on the appropriate tap HIGH MED LOW of the autotransformer For additional wiring details refer to the electrical diagram located on the inside of the control panel TERM LINE VOLTAGE 60 Hz HIGH 283 249 MED 260 230 LOW 236 208 7 18 12 Electric Models Only All electrically heated dryers m...

Страница 14: ... the manufacturer IMPORTANT If connection to this appliance is made with a flexible hose it must be suitable for the appliance category in accordance with national installation regulations of the country of destination and if in doubt the installer must contact the supplier The manufacturer of this appliance does not recommend the use of flexible gas supply line hose An external gas supply shutoff...

Страница 15: ...essible for a pressure gauge connection must be installed in the main gas supply line immediately upstream of the dryers IMPORTANT Pipe joint compounds that resist the action of natural L P and butane gases must be used Test all connections for leaks by brushing on a soapy water solution liquid detergent works well WARNING Never test for leaks with a flame Converting from One Family of Gas to Anot...

Страница 16: ... and affix this label as close as possible to the dryer s existing dryer rating data label plate Affix L P Conversion Rating Label Addendum P N 114090 as close as possible to the dryer s existing dryer rating data label plate Open all shutoff valves reconnect electrical power to the dryer and test for leaks IMPORTANT Never test for leaks with an open flame Use a soapy water solution or product int...

Страница 17: ...onversions done improperly can result in a fire or explosion Gas Pressure Testing For proper operation the gas pressure must be correct consistent and maintained at the gas pressure rates shown on page 15 Provisions are made at the gas valve for taking gas pressure readings There are two types of devices used to measure gas pressure They are the spring mechanical type gauge and the manometer The u...

Страница 18: ...elections Each microprocessor controller computer has been preprogrammed by the factory with the most commonly used parameter program selections If computer program changes are required refer to the computer programming manual which was shipped with the dryer Preoperational Instructions __________ IMPORTANT For more detailed information regarding the microprocessor controller computer refer to the...

Страница 19: ...e After Each Load Clean the lint screen after each load A clogged lint screen will cause poor dryer performance The lint door is located just below the loading door of the dryer Open the lint door brush the lint off the lint screen and remove the lint Inspect lint screen and replace if damaged Weekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area WA...

Страница 20: ...___________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ______...

Страница 21: ..._________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________...

Страница 22: ...Part No 112819 ...

Отзывы: