Laundrylux DAWF0 SERIES Скачать руководство пользователя страница 14

14

112819-1

Gas Information ______________________

It  is  your  responsibility  to  have  all  plumbing  connections,

materials,  and  workmanship  conform  to  local  and  state

regulations  or  codes  of  the  country  of  destination.    In  the

absence of such codes, all plumbing connections, materials,

and  workmanship  must  conform  to  the  applicable  local

requirements.  In the USA this is the National Fuel Gas Code

ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian

Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or

CAN/CGAB149.2-M91 (L.P. Gas) or LATEST EDITION.
It is important that gas pressure regulators meet applicable

pressure requirements, and that gas meters be rated for the

total amount of all the appliance Btu being supplied.

IMPORTANT: 

Failure to comply with these codes or

ordinances, and/or the requirements stipulated in this

manual, can result in personal injury and improper

operation of the dryer.
For ease of service, the individual gas supply line of each

dryer must have its own manual shutoff valve.
The dryer and its individual shutoff valve must be

disconnected from the gas supply piping system during

any pressure testing of that system at test pressures in

excess of 1/2 psig (3.5 kPa).
Failure to isolate or disconnect the dryer from supply as

noted can cause irreparable damage to the gas valve,

voiding the warranty.

!

 WARNING

Fire  or  explosion  could  result  due  to  failure  of
isolating or disconnecting the gas supply as noted.

NOTE: 

Undersized gas piping will result in ignition

problems, slow drying, increased use of energy, and can

create a safety hazard.

The dryer must be connected to the type of heat/gas indicated

on the data label and pressure must be confirmed.  If this

information does not agree with the type of gas available, do

not operate the dryer.  Contact the reseller who sold the dryer

or contact the manufacturer.
The input ratings shown on the data label are for elevations

up to 2,000 feet (610 meters), unless elevation requirements

of over 2,000 feet (610 meters) were specified at the time

the dryer order was placed with the factory.  The adjustment

or conversion of dryers in the field for elevations over 2,000

feet (610 meters) is made by changing each burner orifice.

If this conversion is necessary, contact the reseller who sold

the dryer or contact the manufacturer.

IMPORTANT: 

If connection to this appliance is made with

a flexible hose, it must be suitable for the appliance

category in accordance with national installation

regulations of the country of destination, and if in doubt the

installer must contact the supplier.  The manufacturer of

this appliance does not recommend the use of flexible gas

supply line/hose.  An external gas supply shutoff must be

provided.
Pipe joint compounds that resist the action of natural,

propane, and butane gases must be used.

For added personal safety, when possible, it is suggested

that  a  separate  ground  wire  (size  per  local  codes)  be

connected  from  the  ground  connection  of  the  dryer  to  a

grounded cold water pipe.  Do not ground to a gas pipe or

hot water pipe.  The grounded cold water pipe must have

metal-to-metal connection all the way to the electrical ground.

If there are any nonmetallic interruptions, such as, a meter,

pump,  plastic,  rubber,  or  other  insulating  connectors,  they

must be jumped out with a wire (size per local codes) and

securely clamped to bare metal at both ends.

IMPORTANT: 

For personal safety and proper operation,

the dryer must be grounded.

Provisions are made for ground connection in each dryer at

the electrical service connection area.

!

 WARNING

Electrical Grounding Instructions – The 120 Volt gas
models are equipped with a 3-prong (grounding) plug
for your protection against shock hazard and should
be plugged directly into a properly grounded 3-prong
receptacle.    Do  not  cut  or  remove  the  grounding
prong from this plug.

Electrical Connections

A  wiring  diagram  is  located  behind  the  control  panel  for

connection data.
If local codes permit, power to the dryer can be made by the

use of a flexible UL listed power cord/pigtail (wire size must

conform to rating of dryer), or the dryer can be hard wired

directly to the service breaker panel.  In both cases, a strain

relief must be installed where the wiring enters the dryer.

Wiring Connections / Hookup

All  gas  model  dryers  are  120  Volt,  and  come  with  an

integrated 3-prong NEMA plug.
All electrically heated dryers are 208-240 Volt single-phase

that require grounding.  A ground lug has been provided for

this purpose.
The electrical input connections are made into the rear service

box  located  at  the  upper  right  area  of  the  dryer.   To gain

access, the service box cover must be removed.
Input connection wiring must be sized properly to handle the

dryer’s current draw.  This information is printed on the dryer’s

data label.

Содержание DAWF0 SERIES

Страница 1: ...ass by itself Part No 112819 1 Laundrylux 461 Doughty Boulevard Inwood NY 11096 0338 www laundrylux com Service 516 371 0700 Parts 516 271 2000 DAWF0 and DAWS0 SERIES DRYERS D R Y E R I N S T A L L AT I O N M A N U A L ...

Страница 2: ...nical instructions which will provide the necessary information concerning the modification of the appliance to the condition of use for the country In accordance with EN ISO 3166 1 the names of countries shall be represented by the following codes GB United Kingdom IE Ireland Retain This Manual in a Safe Place for Future Reference This product embodies advanced concepts in engineering design and ...

Страница 3: ...sachusetts If using a ball valve it shall be a T handle type A flexible gas connector when used must not exceed 3 feet WARNING Children should not be allowed to play on or near the dryer s Children should be supervised if near dryer s in operation Under no circumstances should the dryer door switch es lint door switch es or heat safety circuit s ever be disabled Do not modify this appliance The dr...

Страница 4: ...cooking oil constitute a fire hazard and should not be placed in a tumble dryer Do not dry mop heads Contamination by wax or flammable solvents will create a fire hazard WARNING Do not use heat for drying articles that contain plastic foam sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be ...

Страница 5: ...___________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed fro...

Страница 6: ...ø 2w 60 Hz APPROXIMATE NET WEIGHT 176 lb 79 83 kg APPROXIMATE SHIPPING WEIGHT 198 lb 89 81 kg AIRFLOW 220 cfm 6 23 cmm HEAT INPUT 26 000 Btu hr 6 550 kcal hr EXHAUST CONNECTION DIAMETER 4 10 16 cm NATURAL GAS SUPPLY PRESSURE 6 12 in WC NATURAL GAS MANIFOLD PRESSURE 3 in WC L P SUPPLY PRESSURE 11 in WC L P MANIFOLD PRESSURE 10 5 in WC INLET PIPE CONNECTION 3 8 M N P T VOLTAGE AVAILABLE 208 240V 1ø ...

Страница 7: ... Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation TopControl ...

Страница 8: ...8 112819 1 Specifications _____________________________________________________________________ Bottom Control Stackable ...

Страница 9: ...st Requirements section The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combusti...

Страница 10: ...ng out of the top of the washer There are two Feed both harnesses into the bottom of the dryer using the rear cutout hole Do not feed through the coin access funnel hole See diagram Non metered card and non coin installations do not need to interconnect harnesses between the washer and dryer Align the dryer mounting holes over the threaded adapter plate holes The front of the washer and dryer will...

Страница 11: ... of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts overlap the duct being connected All ductwork joints must be taped to prevent moisture and lint from escaping into the building Back draft dampers must be installed in all commonly d...

Страница 12: ...e ductwork must be increased Vertical Venting When vertical dryer venting is used the length of the ductwork from the dryer to the outside exhaust outlet must not exceed 12 feet 3 66 meters The diameter of this ductwork must be 4 inches 10 16 cm Including tumbler dryer elbow connections or elbows used for outside protection from the weather no more than 3 elbows should be used in the exhaust duct ...

Страница 13: ...just the autotransformer located near the burner assembly To adjust the autotransformer wiring place the red wire on the appropriate tap HIGH MED LOW of the autotransformer For additional wiring details refer to the electrical diagram located on the inside of the control panel TERM LINE VOLTAGE 60 Hz HIGH 283 249 MED 260 230 LOW 236 208 7 18 12 Electric Models Only All electrically heated dryers m...

Страница 14: ... the manufacturer IMPORTANT If connection to this appliance is made with a flexible hose it must be suitable for the appliance category in accordance with national installation regulations of the country of destination and if in doubt the installer must contact the supplier The manufacturer of this appliance does not recommend the use of flexible gas supply line hose An external gas supply shutoff...

Страница 15: ...essible for a pressure gauge connection must be installed in the main gas supply line immediately upstream of the dryers IMPORTANT Pipe joint compounds that resist the action of natural L P and butane gases must be used Test all connections for leaks by brushing on a soapy water solution liquid detergent works well WARNING Never test for leaks with a flame Converting from One Family of Gas to Anot...

Страница 16: ... and affix this label as close as possible to the dryer s existing dryer rating data label plate Affix L P Conversion Rating Label Addendum P N 114090 as close as possible to the dryer s existing dryer rating data label plate Open all shutoff valves reconnect electrical power to the dryer and test for leaks IMPORTANT Never test for leaks with an open flame Use a soapy water solution or product int...

Страница 17: ...onversions done improperly can result in a fire or explosion Gas Pressure Testing For proper operation the gas pressure must be correct consistent and maintained at the gas pressure rates shown on page 15 Provisions are made at the gas valve for taking gas pressure readings There are two types of devices used to measure gas pressure They are the spring mechanical type gauge and the manometer The u...

Страница 18: ...elections Each microprocessor controller computer has been preprogrammed by the factory with the most commonly used parameter program selections If computer program changes are required refer to the computer programming manual which was shipped with the dryer Preoperational Instructions __________ IMPORTANT For more detailed information regarding the microprocessor controller computer refer to the...

Страница 19: ...e After Each Load Clean the lint screen after each load A clogged lint screen will cause poor dryer performance The lint door is located just below the loading door of the dryer Open the lint door brush the lint off the lint screen and remove the lint Inspect lint screen and replace if damaged Weekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area WA...

Страница 20: ...___________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ______...

Страница 21: ..._________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________...

Страница 22: ...Part No 112819 ...

Отзывы: