Preoperational Test __________________

All dryers are thoroughly tested and inspected before leaving

the  factory.    However,  a  preoperational  test  should  be

performed before the dryer is publicly used.  It is possible

that adjustments have changed in transit or due to marginal

location (installation) conditions.  Installer must instruct the

user on how to correctly operate the dryer before leaving.
Turn on electric power to the dryer.
Refer to the Operating Instructions for starting your particular

model dryer.

Gas Dryers

Open all shutoff valves.
When a gas dryer is first started (during initial start-up), it

has a tendency not to ignite on the first ignition attempt.  This

is because the gas supply piping is filled with air, so it may

take a few minutes for the air to be purged from the lines.

NOTE: 

During the purging period, check to be sure that all

gas shutoff valves are open.

A gas pressure test should be taken at the gas valve pressure

tap of each dryer to ensure that the water column pressure is

correct and consistent.

NOTE: 

Water column pressure requirements (measured at

the pressure tap of the gas valve body) must be verified.

IMPORTANT: 

In most cases there is no regulator provided

in an L.P. dryer.  The water column pressure must be

regulated at the source (L.P. tank), or an external regulator

must be added to each dryer.

Electrical Dryers

Check  to  ensure  that  electric  oven/contactor  assembly  is

activating.

Safety Related Circuits

Make  a  complete  operational  check  of  all  safety  related

circuits:

• Door Switch(es)
• Hi-Limit Thermostats

Make a complete operational check of all operating controls.

Tumbler Coating

The tumbler is treated with a protective coating.  We suggest

dampening old garments or cloth material with a solution of

water and nonflammable mild detergent and tumbling them

in the tumbler to remove this coating.

Microprocessor Programs/Selections

Each  microprocessor  controller  (computer)  has  been

preprogrammed by the factory with the most commonly used

parameter  (program)  selections.    If  computer  program

changes  are  required,  refer  to  the  computer  programming

manual, which was shipped with the dryer.

Preoperational Instructions __________

IMPORTANT: 

For more detailed information regarding the

microprocessor controller (computer), refer to the

microprocessor user’s manual included with the dryer.

Coin Models

Microprocessor Controller (Computer)

When the microprocessor controller (computer) is in the ready

state,  the  L.C.D.  screen  will  display  “FILL”  and  (XX.XX)

Amount.
Insert coin(s).  Once the correct “Amount to Start” has been

inserted, the L.C.D. will display “PUSH”.
Select temperature by pressing “HI,” “LO,” or “PERM PRESS.”

The cycle will start and the L.C.D. will display the temperature

cycle selected and the remaining time.
The dryer will continue through the drying and cooling cycles,

until the vended time has expired.

NOTE: 

To stop the dryer, open main door.  Continuation of

the cycle will resume only after the door has been closed

and any one of the three temperature selections is

pressed.

Non-Coin Models

Microprocessor Controller (Computer)

The L.E.D. display reads “FILL” (no cycle in progress).
Select temperature by pressing “HI,” “LO,” or “PERM PRESS.”
The dryer will then start (i.e. blower, tumbler, and heat).
The L.E.D. will display the temperature cycle selected and

the remaining time.

NOTE: 

The dryer can be stopped at any time by opening

the main door or the lint door.

When  the  programmed  drying  time  has  expired,  the  non-

coin microprocessor controller (computer) will proceed into

the Cool Down Cycle.

Shutdown Instructions _______________

If  the  dryer  is  to  be  shutdown  (taken  out  of  service)  for  a

period of time, the following must be performed:
Discontinue  power  to  the  dryer  either  at  the  external

disconnect switch or the circuit breaker.
Discontinue the heat supply:

Gas Models

 – Discontinue the gas supply.

Shut off external gas supply shutoff valve.
Shut off internal gas supply shutoff valve located in the gas

valve burner area.

Содержание DAWF0 SERIES

Страница 1: ...ass by itself Part No 112819 1 Laundrylux 461 Doughty Boulevard Inwood NY 11096 0338 www laundrylux com Service 516 371 0700 Parts 516 271 2000 DAWF0 and DAWS0 SERIES DRYERS D R Y E R I N S T A L L AT I O N M A N U A L ...

Страница 2: ...nical instructions which will provide the necessary information concerning the modification of the appliance to the condition of use for the country In accordance with EN ISO 3166 1 the names of countries shall be represented by the following codes GB United Kingdom IE Ireland Retain This Manual in a Safe Place for Future Reference This product embodies advanced concepts in engineering design and ...

Страница 3: ...sachusetts If using a ball valve it shall be a T handle type A flexible gas connector when used must not exceed 3 feet WARNING Children should not be allowed to play on or near the dryer s Children should be supervised if near dryer s in operation Under no circumstances should the dryer door switch es lint door switch es or heat safety circuit s ever be disabled Do not modify this appliance The dr...

Страница 4: ...cooking oil constitute a fire hazard and should not be placed in a tumble dryer Do not dry mop heads Contamination by wax or flammable solvents will create a fire hazard WARNING Do not use heat for drying articles that contain plastic foam sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be ...

Страница 5: ...___________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed fro...

Страница 6: ...ø 2w 60 Hz APPROXIMATE NET WEIGHT 176 lb 79 83 kg APPROXIMATE SHIPPING WEIGHT 198 lb 89 81 kg AIRFLOW 220 cfm 6 23 cmm HEAT INPUT 26 000 Btu hr 6 550 kcal hr EXHAUST CONNECTION DIAMETER 4 10 16 cm NATURAL GAS SUPPLY PRESSURE 6 12 in WC NATURAL GAS MANIFOLD PRESSURE 3 in WC L P SUPPLY PRESSURE 11 in WC L P MANIFOLD PRESSURE 10 5 in WC INLET PIPE CONNECTION 3 8 M N P T VOLTAGE AVAILABLE 208 240V 1ø ...

Страница 7: ... Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation TopControl ...

Страница 8: ...8 112819 1 Specifications _____________________________________________________________________ Bottom Control Stackable ...

Страница 9: ...st Requirements section The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combusti...

Страница 10: ...ng out of the top of the washer There are two Feed both harnesses into the bottom of the dryer using the rear cutout hole Do not feed through the coin access funnel hole See diagram Non metered card and non coin installations do not need to interconnect harnesses between the washer and dryer Align the dryer mounting holes over the threaded adapter plate holes The front of the washer and dryer will...

Страница 11: ... of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts overlap the duct being connected All ductwork joints must be taped to prevent moisture and lint from escaping into the building Back draft dampers must be installed in all commonly d...

Страница 12: ...e ductwork must be increased Vertical Venting When vertical dryer venting is used the length of the ductwork from the dryer to the outside exhaust outlet must not exceed 12 feet 3 66 meters The diameter of this ductwork must be 4 inches 10 16 cm Including tumbler dryer elbow connections or elbows used for outside protection from the weather no more than 3 elbows should be used in the exhaust duct ...

Страница 13: ...just the autotransformer located near the burner assembly To adjust the autotransformer wiring place the red wire on the appropriate tap HIGH MED LOW of the autotransformer For additional wiring details refer to the electrical diagram located on the inside of the control panel TERM LINE VOLTAGE 60 Hz HIGH 283 249 MED 260 230 LOW 236 208 7 18 12 Electric Models Only All electrically heated dryers m...

Страница 14: ... the manufacturer IMPORTANT If connection to this appliance is made with a flexible hose it must be suitable for the appliance category in accordance with national installation regulations of the country of destination and if in doubt the installer must contact the supplier The manufacturer of this appliance does not recommend the use of flexible gas supply line hose An external gas supply shutoff...

Страница 15: ...essible for a pressure gauge connection must be installed in the main gas supply line immediately upstream of the dryers IMPORTANT Pipe joint compounds that resist the action of natural L P and butane gases must be used Test all connections for leaks by brushing on a soapy water solution liquid detergent works well WARNING Never test for leaks with a flame Converting from One Family of Gas to Anot...

Страница 16: ... and affix this label as close as possible to the dryer s existing dryer rating data label plate Affix L P Conversion Rating Label Addendum P N 114090 as close as possible to the dryer s existing dryer rating data label plate Open all shutoff valves reconnect electrical power to the dryer and test for leaks IMPORTANT Never test for leaks with an open flame Use a soapy water solution or product int...

Страница 17: ...onversions done improperly can result in a fire or explosion Gas Pressure Testing For proper operation the gas pressure must be correct consistent and maintained at the gas pressure rates shown on page 15 Provisions are made at the gas valve for taking gas pressure readings There are two types of devices used to measure gas pressure They are the spring mechanical type gauge and the manometer The u...

Страница 18: ...elections Each microprocessor controller computer has been preprogrammed by the factory with the most commonly used parameter program selections If computer program changes are required refer to the computer programming manual which was shipped with the dryer Preoperational Instructions __________ IMPORTANT For more detailed information regarding the microprocessor controller computer refer to the...

Страница 19: ...e After Each Load Clean the lint screen after each load A clogged lint screen will cause poor dryer performance The lint door is located just below the loading door of the dryer Open the lint door brush the lint off the lint screen and remove the lint Inspect lint screen and replace if damaged Weekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area WA...

Страница 20: ...___________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ______...

Страница 21: ..._________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________...

Страница 22: ...Part No 112819 ...

Отзывы: