background image

112819-1

11

EXAMPLE:  For  a  bank  of  four  dryers,  two  unrestricted

openings measuring 10-inches by 6-inches (25.4 cm by 15.24

cm) are acceptable.

IMPORTANT: 

Make-up air must be free of dry cleaning

solvent fumes.  Make-up air that is contaminated by dry

cleaning solvent fumes will result in irreparable damage to

the motors and other dryer components.

Exhaust Requirements _______________

Exhaust  ductwork  should  be  designed  and  installed  by  a

qualified professional.  Improperly sized ductwork will create

excessive  back  pressure,  which  results  in  slow  drying,

increased use of energy, and shutdown of the burner by the

burner hi-limits or blower housing hi-limit protector thermostat.

The  dryer  must  be  installed  with  a  proper  exhaust  duct

connection to the outside.
The dryer shall not be exhausted into any gas vent, chimney,

wall, ceiling or concealed space of a building.
The  design  of  the  flue  system  shall  be  such  that  any

condensate formed when operating the appliance from cold

shall either be retained and subsequently re-evaporated or

discharged.

CAUTION: This dryer produces combustible lint and
must be exhausted to the outdoors.

Improperly sized or installed exhaust ductwork can
create a potential fire hazard.

A = 10-inches (25.4 cm)
B = 6-inches (15.24 cm)

To compensate for the use of registers or louvers used over

the openings, this area must be increased by approximately

33%.  Make-up air openings should not be located in an area

directly near where exhaust vents exit the building.
Allowances  must  be  made  for  remote  or  constricting

passageways or where dryers are located at high altitudes

or predominantly low pressure areas.

NOTE: 

Component failure due to dry cleaning solvent

fumes will void the warranty.

The  ductwork  should  be  laid  out  in  such  a  way  that  the

ductwork travels as directly as possible to the outdoors with

as  few  turns  as  possible.    There  should  be  a  minimum

6-inch  (15.24  cm)  clearance  between  the  back  guard  and

the first bend in the ductwork for ease of servicing.  Single or

independent dryer venting is recommended.  It is suggested

that the use of 90° turns be avoided; use 30° and/or 45° bends

instead.    The  radius  of  the  elbows  should  preferably  be

1-1/2 times the diameter of the duct.  All ductwork should be

smooth inside with no projections from sheet metal screws

or other obstructions, which will collect lint.  When adding

ducts, overlap the duct being connected.  All ductwork joints

must  be  taped  to  prevent  moisture  and  lint  from  escaping

into the building.  Back draft dampers must be installed in all

commonly  ducted  systems.    Inspection  doors  should  be

installed  at  strategic  points  in  the  exhaust  ductwork  for

periodic inspection and cleaning of lint from the ductwork.

IMPORTANT: 

It is recommended that exhaust or booster

fans not be used in the exhaust ductwork system.
Exhaust back pressure measured by a manometer/

magnehelic in the exhaust duct must be no less than 0 and

must not exceed 0.6 in WC (1.48 mb).

NOTE: 

When the exhaust ductwork passes through a wall,

ceiling, or roof made of combustible materials, the opening

must be 2-inches (5.08 cm) larger than the duct (all the

way around).  The duct must be centered within this

opening.
As per the National Fuel Gas Code, “Exhaust ducts for

type 2 clothes dryers shall be constructed of sheet metal or

other noncombustible material.  Such ducts shall be

equivalent in strength and corrosion resistance to ducts

made of galvanized sheet steel not less than 26 gauge

(0.0195-inches [0.50 mm]) thick.”

The  ductwork  for  this  appliance  must  be  suitable  for  the

appliance category in accordance with national installation

regulations of the country of destination.

Outside Ductwork Protection

To protect the outside end of the horizontal ductwork from

the weather, a 90° elbow bent downward should be installed

where the exhaust exits the building.  If the ductwork travels

vertically up through the roof, it should be protected from the

weather by using a 180° turn to point the opening downward.

In either case, allow at least twice the diameter of the duct

between the duct opening and the nearest obstruction (refer

to the diagram).

IMPORTANT: 

Do not use screens, louvers, or caps on the

outside opening of the exhaust ductwork.

Single Dryer Venting

IMPORTANT: 

For extended ductwork runs, the cross-

sectional area of the ductwork can only be increased to an

extent.  When the ductwork approaches the maximum

limits as noted in this manual, a professional HVAC firm

should be consulted for proper venting information.

Содержание DAWF0 SERIES

Страница 1: ...ass by itself Part No 112819 1 Laundrylux 461 Doughty Boulevard Inwood NY 11096 0338 www laundrylux com Service 516 371 0700 Parts 516 271 2000 DAWF0 and DAWS0 SERIES DRYERS D R Y E R I N S T A L L AT I O N M A N U A L ...

Страница 2: ...nical instructions which will provide the necessary information concerning the modification of the appliance to the condition of use for the country In accordance with EN ISO 3166 1 the names of countries shall be represented by the following codes GB United Kingdom IE Ireland Retain This Manual in a Safe Place for Future Reference This product embodies advanced concepts in engineering design and ...

Страница 3: ...sachusetts If using a ball valve it shall be a T handle type A flexible gas connector when used must not exceed 3 feet WARNING Children should not be allowed to play on or near the dryer s Children should be supervised if near dryer s in operation Under no circumstances should the dryer door switch es lint door switch es or heat safety circuit s ever be disabled Do not modify this appliance The dr...

Страница 4: ...cooking oil constitute a fire hazard and should not be placed in a tumble dryer Do not dry mop heads Contamination by wax or flammable solvents will create a fire hazard WARNING Do not use heat for drying articles that contain plastic foam sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be ...

Страница 5: ...___________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed fro...

Страница 6: ...ø 2w 60 Hz APPROXIMATE NET WEIGHT 176 lb 79 83 kg APPROXIMATE SHIPPING WEIGHT 198 lb 89 81 kg AIRFLOW 220 cfm 6 23 cmm HEAT INPUT 26 000 Btu hr 6 550 kcal hr EXHAUST CONNECTION DIAMETER 4 10 16 cm NATURAL GAS SUPPLY PRESSURE 6 12 in WC NATURAL GAS MANIFOLD PRESSURE 3 in WC L P SUPPLY PRESSURE 11 in WC L P MANIFOLD PRESSURE 10 5 in WC INLET PIPE CONNECTION 3 8 M N P T VOLTAGE AVAILABLE 208 240V 1ø ...

Страница 7: ... Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation TopControl ...

Страница 8: ...8 112819 1 Specifications _____________________________________________________________________ Bottom Control Stackable ...

Страница 9: ...st Requirements section The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combusti...

Страница 10: ...ng out of the top of the washer There are two Feed both harnesses into the bottom of the dryer using the rear cutout hole Do not feed through the coin access funnel hole See diagram Non metered card and non coin installations do not need to interconnect harnesses between the washer and dryer Align the dryer mounting holes over the threaded adapter plate holes The front of the washer and dryer will...

Страница 11: ... of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts overlap the duct being connected All ductwork joints must be taped to prevent moisture and lint from escaping into the building Back draft dampers must be installed in all commonly d...

Страница 12: ...e ductwork must be increased Vertical Venting When vertical dryer venting is used the length of the ductwork from the dryer to the outside exhaust outlet must not exceed 12 feet 3 66 meters The diameter of this ductwork must be 4 inches 10 16 cm Including tumbler dryer elbow connections or elbows used for outside protection from the weather no more than 3 elbows should be used in the exhaust duct ...

Страница 13: ...just the autotransformer located near the burner assembly To adjust the autotransformer wiring place the red wire on the appropriate tap HIGH MED LOW of the autotransformer For additional wiring details refer to the electrical diagram located on the inside of the control panel TERM LINE VOLTAGE 60 Hz HIGH 283 249 MED 260 230 LOW 236 208 7 18 12 Electric Models Only All electrically heated dryers m...

Страница 14: ... the manufacturer IMPORTANT If connection to this appliance is made with a flexible hose it must be suitable for the appliance category in accordance with national installation regulations of the country of destination and if in doubt the installer must contact the supplier The manufacturer of this appliance does not recommend the use of flexible gas supply line hose An external gas supply shutoff...

Страница 15: ...essible for a pressure gauge connection must be installed in the main gas supply line immediately upstream of the dryers IMPORTANT Pipe joint compounds that resist the action of natural L P and butane gases must be used Test all connections for leaks by brushing on a soapy water solution liquid detergent works well WARNING Never test for leaks with a flame Converting from One Family of Gas to Anot...

Страница 16: ... and affix this label as close as possible to the dryer s existing dryer rating data label plate Affix L P Conversion Rating Label Addendum P N 114090 as close as possible to the dryer s existing dryer rating data label plate Open all shutoff valves reconnect electrical power to the dryer and test for leaks IMPORTANT Never test for leaks with an open flame Use a soapy water solution or product int...

Страница 17: ...onversions done improperly can result in a fire or explosion Gas Pressure Testing For proper operation the gas pressure must be correct consistent and maintained at the gas pressure rates shown on page 15 Provisions are made at the gas valve for taking gas pressure readings There are two types of devices used to measure gas pressure They are the spring mechanical type gauge and the manometer The u...

Страница 18: ...elections Each microprocessor controller computer has been preprogrammed by the factory with the most commonly used parameter program selections If computer program changes are required refer to the computer programming manual which was shipped with the dryer Preoperational Instructions __________ IMPORTANT For more detailed information regarding the microprocessor controller computer refer to the...

Страница 19: ...e After Each Load Clean the lint screen after each load A clogged lint screen will cause poor dryer performance The lint door is located just below the loading door of the dryer Open the lint door brush the lint off the lint screen and remove the lint Inspect lint screen and replace if damaged Weekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area WA...

Страница 20: ...___________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ______...

Страница 21: ..._________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________...

Страница 22: ...Part No 112819 ...

Отзывы: