L’ARTISTICO SRL |
EN
33
Cod. 40115 | Rev. 17 | 11/2020
WARNING: Mechanical extraction and extraction
fans (VMC, extractor hoods, etc.), when used in the
same room or space as the appliance, can cause
combustion problems: in this case it is mandatory to
connect the external air intake directly to the 'device.
21. MAIN PELLET LOAD TANK
The opening of the sliding door for pellet loading varies depending on
the models. The corner and 3 glass models have a loading door on
both lateral sides. On the other models the opening of the slide door
for pellet loading is on the right side at the top (looking at the fireplace
in front).
WARNING: The pellet loading door must remain
closed when operating the appliance.
The use of the appliance with the open door is
prohibited as it alters all combustion values.
FUEL LOADING
To load the pellet into the tank it is advisable to cut a corner of the bag
and empty it slowly into the tank. Make sure there are no foreign
objects in the bag.
WARNING: It is forbidden to leave the pellet on the
hot parts of the appliance especially on the top cover,
FIRE WARNING. During loading, make sure that the
plastic bag / paper does not come into contact with the
hot areas of the appliance. Do not overfill the tank with
the risk of leakage of the pellet.
Pellet is packed in plastic or paper bags. Do carefully stock it to allow
humidity from damaging it..
WARNING: Do not allow the accumulation of
sawdust on the bottom of the tank, monthly aspirate the
deposited sawdust inside the main tank.
During operation, if you notice that the pellet hopper is empty,
DO NOT LOAD PELLETS IN THE TANK with the appliance on.
Switch off the appliance with the ON / OFF button and only after
finishing the final cleaning and the chimney has turned OFF, can you
refill the pellets in the tank, clean the brazier and the combustion
chamber and turn on the device. If the described procedure is not
carried out, there may be an accumulation of pellets in the burner with
the flame out, with the consequent risk of gas formation and possible
internal explosion.
22. ELECTRICAL CONNECTION
Check for the wall plug to be adequate to the stove electrical
requirements: 230V/50Hz and 350Watt. Make sure the electrical cord
doesn’t get in touch with any hot part of the stove, doesn’t run over
the smoke connection, a proper earth is available and a proper circuit
breaker is fitted. In case of irregular power supply (normally in remote
or mountain areas), do not worry, your stove is protected with two
5X20 4A STD between the main switch and the cord plug on the rear
panel. Check the fuses before installing the stove.
Ensure that the plug for the electrical connection is accessible after
the installation of the device and in its definitive position is not heated
by radiation or by contact with hot parts.
Voltage variations greater than 10% of the nominal value, may affect
the proper functioning of the product causing anomalies to its
electrical system.
CAUTION: The electrical system must be fitted
with a suitable earth circuit conforms to the 72/23 EEC
standards, 93/98 EEC.
JACK POWER
CABLE
SLOT 2
REMOVABLE
FUSE
ON / OFF
SWITCH
23. EMERGENCY CONTROL PANEL
It comes complete with its plasterboard recessed box. The control
panel acts as a receiver for the remote control and must be operated
manually only for emergency operation in the event of breakdown or
loss of the remote control.
WARNING: it should be positioned so that it is
visible and accessible. It may also not be visible on the
external plasterboard as it communicates via radio with
the remote control.