background image

 

 

PYROMANIA FIRE FEATURE MANUAL 

 
 
 

 
 

 
 

 

 

 

 

                                  

 

ALCHEMY 

FACTORY MODEL GAS4212-B (IAW) 

 
 

 

 

 

 

 

 

 
 
 
 
 

 

 
 

DANGER 

CARBON MONOXIDE HAZARD 

This appliance can produce carbon 
monoxide which has no odor. 
Using it in an enclosed space can kill you. 
Never use this appliance in an enclosed 

space such as a camper, tent, car or home

 

 

WARNING 

Do not store or use gasoline, or 

other flammable vapors and 

liquids,in the vicinity of this or any 

other appliance. 

An LP-cylinder not connected for 

use shall not be stored in vicinity 

of this or any other appliance. 

 

 

 

DANGER 

FIRE OR EXPLOSION HAZARD 

If you smell gas: 

 

Shut off gas to the appliance. 

 

Extinguish any open flame. 

 

If odor continues, leave the 

area immediately. 

 

After leaving the area, call 

your gas supplier or fire 

department. 

Failure to follow these instructions 

could result in fire or explosion, 

which could cause property 

damage, personal injury or death. 

INSTALLER: Leave this manual with the appliance. 
CONSUMER: Retain this manual for future reference. 

WARNING 

If the information in this manual is not followed exactly, 

a fire or explosion may result causing property damage, 

personal injury, or loss of life. 

 

WARNING: 

For Outdoor Use Only. 

Installation and service must be performed by a qualified 

installer, service agency, or the gas supplier. 

SM-5Y7705(CSA) 

Summary of Contents for ALCHEMY

Page 1: ...LOSION HAZARD If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues leave the area immediately After leaving the area call your gas supplier or fire department Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death INSTALLER Leave this manual with the appliance CONSUMER Retain this manua...

Page 2: ...quirements 4 Connections liquid propane LPG 5 Connections natural gas NG 6 Conversion instructions propane to natural gas 7 Battery installation 8 Leak test 8 Lava rock installation 9 Operation instructions 10 Pre use instructions 10 Operation warnings 11 lighting 11 Shutting off 11 Notes 11 Cleaning maintenance and storage 12 Cleaning and maintenance 12 Storage 12 Troubleshooting 13 Replacement p...

Page 3: ... damage is found contact the retailer and report it immediately Tighten any loose connections and perform a leak test afterward Check the gas supply hose assembly for damage The hose assembly must be replaced prior to the appliance being put into use if any evidence of damage is found The replacement hose assembly must be one specified by Pyromania Inc in the parts list located on page 15 LEG INST...

Page 4: ...ies with the standard for Quick Disconnect Devices for Gas Fuel Appliances ANSI Z21 41 CSA6 9 There MUST be a pressure regulator with a maximum output of pressure of 14 W C installed in line When an appliance is for connection to a fixed piping system the installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 National Fuel Ga...

Page 5: ...around it clear and free from combustible materials Gasoline and other flammable vapors and liquids must be kept a minimum of 25 feet away and auxiliary propane tanks should be stored at a minimum of 10 feet away VENTILATION REQUIREMENTS Fresh air must be able to pass under this appliance to safeguard against residual gas accumulation Failure to allow proper ventilation may cause a fire or explosi...

Page 6: ...gram A B Tighten down the screw on the side of the tank seat to secure the propane tank refer to diagram B C Place the propane tank a minimum of 60 152 4CM away from the fire feature refer to diagram C Diagram A Diagram B Diagram C 2 Check to make sure that there is no debris in head of the propane tank or in the regulator at the end of the supply hose Connect the gas line to the tank by turning t...

Page 7: ...ed This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa The supply gas hose must not be run along areas where it may be a tripping hazard or subjected to accidental damage such as pathways driveways and lawns Do not bury the...

Page 8: ...kit onto the rating plate on the converted appliance 8 Perform a leak testing of the converted appliance before operating the converted appliance see the LEAK TEST section of page 8 of the manual Natural gas fire tables are set up to operate on natural gas only at a pressure of seven inches of water column 7 W C Check with your gas utility for local gas pressure Natural gas input rating is 50 000 B...

Page 9: ... soap to one part water 2 Make sure the appliance control knob is in the OFF position 3 Open the gas supply to the fire table 4 Apply the leak testing solution by spraying it on joints of the gas delivery system Blowing bubbles in the soap solution indicates that a leak is present 5 Stop a leak by tightening the loose joint or by replacing the faulty part with one specified by the manufacturer If ...

Page 10: ...e bag into the burner in order to prevent damage to the fire table to prevent clogging the burner ports with dust and to prevent getting debris in the ignitor box Only place enough lava rock to cover the top of the burner ring and pan by 1 Do not cover the top of the ignitor box Excessive material may impede gas flow and cause gas build up and potentially cause an explosion CORRECT INCORRECT I ...

Page 11: ...ase of the fire table because they are the two areas that gas would most likely accumulate in case of a leak If you smell gas do not try to light the appliance Immediately close the manual shut off valve leave the area and call your gas supplier OPERATION WARNINGS Children must not operate this appliance and should be closely supervised when they are in the area of the appliance Clothing or other ...

Page 12: ...eight is 8 to 13 USING A LONG MATCH OR BBQ LIGHTER 1 Make sure that the burner control knob is in the OFF position 2 Prior to lighting clear some lava rock away from the burner ring with a garden trowel to gain access to the burner holes 3 Wearing heat resistant gloves position the flame of the match or BBQ lighter near the exposed burner holes Do not lean over the fire table while lighting 4 Pres...

Page 13: ... the hose assembly for excessive abrasion or wear The hose assembly must be replaced prior to the appliance being put into use if any evidence of damage is found The replacement hose assembly must be one specified by Pyromania Inc in the parts list located on page 15 FIRE TABLE BODY For routine cleaning of the fire table wipe down with a damp cloth or sponge and mild dish soap Avoid using any othe...

Page 14: ...k the setting of the thermocouple refer to diagram 2 and confirm the connection is tight refer to diagram 3 C The gas pressure is too low Have a gas technician do a pressure test on the supply line D An improper size orifice is installed Replace it with the proper orifice 3 The burner is emitting excessive smoke and or soot A Poor fuel quality Contact your gas supplier B There is too much lava roc...

Page 15: ...correctly or depleted Ensure that a fresh AA battery is installed Positive side facing outward toward the sparker cap B There is corrosion on the battery contacts Check contact at the bottom of the battery cavity for corrosion Clean with a small piece of sandpaper or a file C The battery cap is not screwed down completely If the cap cannot be screwed down tight enough the battery will not make a p...

Page 16: ...e 4 Ground wire 5 Thermocouple 6 Ignitor cover 7 Air mixer 8 Air shutter 9 Orifice 2 16mm for propane 3 73mm for natural gas 10 Orifice holder 11 Natural gas fitting 12 Stainless steel flex pipe 13 Bulkhead fitting 14 Control valve 15 Control knob 16 Ignitor 17 Control panel 18 1 Supply hose propane 18 2 Supply hose natural gas R ...

Reviews: