MINI STARFIRE 9:
air fireplaces with vertical glass
(1) AIR ENTRY IN THE COATING
: it is obligatory to always ensure a
minimum ventilation inlet and outlet in the coating through a grid at the
bottom and a grid above (decompression) of
at least 500 cm2 each
.
They can be done frontally, laterally or even later, provided that the
circle of air entering and leaving is always inside the house (and not
outside).
(2) INSPECTION DOOR:
to load the
pellets into the tank, periodic maintenance
as well as annual cleaning of the chimney
flue, spare parts, it is mandatory to leave
the electronic components on the side (as
standard to right, looking at the chimney
from the front) a sufficient inspection door
to access all the components (pellet load,
control unit, smoke extractor, air fans,
glow plug) of
at least 50x140 cm in
height
.
In addition, on the left side (facing the
chimney face), it is mandatory to carry a
door
at least 30x25 (we recommend
making a removable grille for air inlet).
cm
to clean the flue integrated in the device (we
recommend making a removable grille for air
inlet).
This inspection door can be avoided if on
the right side there is a larger inspection
door, at least 50 x 160 cm high, which must start from the ground and
allow to reach the rear inspection cap on the T.
(3) FRONT OUTPUT OF THE HOT AIR FAN:
The appliance is supplied with a 250 m3 / h rear tangential fan which
pushes the hot air towards the outlet integrated in the front glass..
(4) TOP HOT AIR FAN LINE:
The unit is supplied with two top fans to heat room air:
• A 180 m3 / h right upper centrifugal fan with a hot air outlet of Ø 60
mm that can be traveled up to a maximum distance of 5 meters,
manageable by the remote client (VENT-3) from the speed 0) to 5
(max) or automatic.
• Upper left centrifugal fan 180 m3 / h with hot air outlet Ø 60 mm that
can be traversed up to a maximum distance of 5 meters, manageable
by the remote client (VENT-2) from speed 0) to 5 (max) or automatic.
For optimal installation, we recommend using thermally and
acoustically insulated pipes to ensure the best acoustic and thermal
comfort.