  WARNING:  Mechanical  extraction  and  extraction 

fans  (VMC,  extractor  hoods,  etc.),  when  used  in  the 
same  room  or  space  as  the  appliance,  can  cause 
combustion  problems:  in  this  case  it  is  mandatory  to 
connect the external air intake directly to the 'device. 

 
 

21. MAIN PELLET LOAD TANK 

The opening of the sliding door for pellet loading varies depending on 
the models. The corner and 3 glass models have a loading door on 
both lateral sides. On the other models the opening of the slide door 

for pellet loading is on the right side at the top (looking at the fireplace 
in front). 

 

 

  WARNING:  The  pellet  loading  door  must  remain 

closed when operating the appliance. 
The  use  of  the  appliance  with  the  open  door  is 
prohibited as it alters all combustion values. 

 
 

FUEL LOADING 

To load the pellet into the tank it is advisable to cut a corner of the bag 
and  empty  it  slowly  into  the  tank.  Make  sure  there  are  no  foreign 

objects in the bag. 

 WARNING: It is forbidden to leave the pellet on the 

hot  parts  of  the  appliance  especially  on  the  top  cover, 
FIRE  WARNING.  During  loading,  make  sure  that  the 
plastic bag / paper does not come into contact with the 
hot areas of the appliance. Do not overfill the tank with 
the risk of leakage of the pellet. 

Pellet is packed in plastic or paper bags. Do carefully stock it to allow 

humidity from damaging it.. 
 

  WARNING:  Do  not  allow  the  accumulation  of 

sawdust on the bottom of the tank, monthly aspirate the 
deposited sawdust inside the main tank. 

 

 

 

22. ELECTRICAL CONNECTION 

Check  for  the  wall  plug  to  be  adequate  to  the  stove  electrical 
requirements: 230V/50Hz and 350Watt. Make sure the electrical cord 

doesn’t get in touch with any hot part of the stove, doesn’t run over 

the smoke connection, a proper earth is available and a proper circuit 

breaker is fitted. In case of irregular power supply (normally in remote 
or  mountain  areas),  do  not  worry,  your  stove  is  protected  with  two 

5X20 4A STD between the main switch and the cord plug on the rear 
panel. Check the fuses before installing the stove. 

 

Ensure  that  the  plug  for  the  electrical  connection  is  accessible  after 

the installation of the device and in its definitive position is not heated 
by radiation or by contact with hot parts. 

Voltage variations greater than 10% of the nominal value, may affect 
the  proper  functioning  of  the  product  causing  anomalies  to  its 
electrical system. 

  CAUTION:  The  electrical  system  must  be  fitted 

with  a  suitable  earth  circuit  conforms  to  the  72/23  EEC 
standards, 93/98 EEC. 

 

 

 

JACK POWER 

CABLE 

SLOT 2 

REMOVABLE 

FUSE 

ON / OFF  

SWITCH 

 
 

23. EMERGENCY CONTROL PANEL 

It  comes  complete  with  its  plasterboard  recessed  box.  The  control 
panel acts as a receiver for the remote control and must be operated 

manually only for emergency operation in the event of breakdown or 
loss of the remote control. 

  WARNING:  it  should  be  positioned  so  that  it  is 

visible and accessible. It may also not be visible on the 
external plasterboard as it communicates via radio with 
the remote control. 

 

 

 

24. STARTING AND USING 

Fill the pellet tank before starting any ignition operation. At first charge 

of  pellet  or  when  the  pellet  tank  is  empty,  remember  that  the  load 
auger is empty and therefore takes longer for the first pellet load: Run 
menu 8. 

Содержание APOLLO 15

Страница 1: ...es Installation use and maintenance manual EN Read the instructions carefully before installation use and maintenance The manual is an integral part of the appliance Inserts granul s autoporteurs noti...

Страница 2: ...IZIONI E TERMINI GARANZIA CONVENZIONALE Oggetto della Garanzia L oggetto della Garanzia convenzionale consiste nel ripristino della conformit del bene senza spese per il Consumatore alle condizioni qu...

Страница 3: ...ratto di vendita Installazione dei prodotti non eseguiti a regola d arte in modo non conforme sia alle normative in vigore es dichiarazione di conformit che alle istruzioni contenute in ogni singola c...

Страница 4: ...cali inclusi quelli riferiti alle Norme regionali nazionali ed europee devono essere rispettate nell installazione dell apparecchio nonch le istruzioni contenute nel presente manuale Non vi sar respon...

Страница 5: ...i elementi dell imballo alla portata dei bambini o di persone inabili non assistite In seguito ad un lungo periodo di mancato utilizzo controllare la presenza di eventuali ostruzioni prima di accender...

Страница 6: ...ELLA GARANZIA e l annessa responsabilit del produttore Il fatto di bruciare pellet di scarsa qualit vi porta a riduzione degli intervalli di pulizia aumento del consumo di combustibile e diminuzione d...

Страница 7: ...camino al pavimento mediante l utilizzo di cemento o materiali indurenti per evitare appunto vibrazioni e fenomeni di risonanza generati dai ventilatori montati sull apparecchio DISTANZE MINIME DA MA...

Страница 8: ...o ad una distanza max di 6 metri Il ventilatore gestibile dal cliente da telecomando VENT 3 dalla velocit 0 spento alla 5 max oppure automatica Per un installazione ottimale consigliamo di utilizzare...

Страница 9: ...tello di ispezione sufficiente per accedere a tutti i componenti di almeno 50x140 cm di altezza Lo sportello potrebbe essere fatto anche sul retro o fianco permettendo l accesso a tutto il vano intern...

Страница 10: ...tra fornita rompere i fori preintagliati nel coperchio superiore fissare i 2 collarini da 80 mm con viti e rondelle e canalizzare quindi l aria superiormente fino ad una distanza max di 1 5 metri 4 CA...

Страница 11: ...dai raccordi 14 DEFLETTORI FUMI SUPERIORI Ogni apparecchio pu avere dei deflettori fumi in vermiculite da posizionare in appoggio nella parte alta della camera di combustione Il modello idro MARLIN no...

Страница 12: ...tti della combustione dell apparecchio nel caso la canna fumaria non fosse munita di regolare targhetta segnaletica deve essere richiesta la certificazione a un fumista abilitato L inserimento in cann...

Страница 13: ...e infiammabile X distanza indicata sulla targa della canna fumaria GXXX in mm 20 RACCORDO A PRESA D ARIA ESTERNA La presa d aria esterna deve avere un minimo di 100 mm La norma UNI 10683 o le altre no...

Страница 14: ...segatura depositata all interno del serbatoio principale 22 RACCORDO ELETTRICO Il collegamento alla corrente elettrica avviene mediante normale cavo con presa elettrica omologata Verificate che la pre...

Страница 15: ...e I Verificare che il fusibile di protezione elettrica sia integro Verificare che il serbatoio del pellet sia carico a sufficienza per il periodo di accensione desiderato Verificare che le batterie si...

Страница 16: ...osteriore in vermiculite 3 Con l aiuto di un aspiratore pulire accuratamente il vano scambiatore posto dietro ai pannelli in vermiculite e pulire tutta la camera di combustione dalle particelle di pel...

Страница 17: ...heda elettronica Messa fuori servizio fine stagione A fine di ogni stagione prima di spegnere l apparecchio si consiglia di svuotare completamente il serbatoio del pellet aspirando eventuali residui d...

Страница 18: ...expenses for the Consumer under the conditions specified below The guarantee is exclusively for the repair and or free replacement of components recognized as affected by design manufacturing and con...

Страница 19: ...d out in a workmanlike manner in a manner that does not comply with both the regulations in force eg declaration of conformity and the instructions contained in each individual package and or operated...

Страница 20: ...r declines all responsibility After removing the packaging ensure that the content is intact and complete Otherwise contact the dealer where the appliance was purchased All electric components that ma...

Страница 21: ...erator switched off If this is the case contact your service representative and in any case do not disable security systems If there is a fire in the chimney have adequate systems to suffocate the fla...

Страница 22: ...ual All local regional and prescriptive regulations must also be respected The installation of the hydro products must be carried out in a domestic environment respecting a minimum temperature not low...

Страница 23: ...urniture curtains carpets and flammable fluids at least 100 cm from the appliance when operating MINIMUM DISTANCES FROM NON FLAMMABLE MATERIALS In the case of non flammable materials it is necessary t...

Страница 24: ...and FRATAC EVO M14 models refer to the following diagram to make the correct connections for the upper air connections The hot air from the tangential fan comes out of the two A nozzles 80 mm they mus...

Страница 25: ...be done frontally laterally or even later provided that the circle of air entering and leaving is always inside the house and not outside 2 INSPECTION DOOR to load the pellets into the tank periodic...

Страница 26: ...he pressure switch the thermal safety reset button and the electric lock C The turbolator levers must be operated weekly to clean the tube bundle D Aeration valve E 7 liter expansion tank mounted on t...

Страница 27: ...Soot fire resistance class G All smokestacks connect to appliances burning solid fuel must be soot fire resistant the designation letter will therefore be G followed by the distance in millimeters XX...

Страница 28: ...ONNECTION The outside air intake must have a minimum of 100 mm UNI 10683 or local and national regulations must be respected for the size and presence of external air intake In the presence of gas app...

Страница 29: ...ON Check for the wall plug to be adequate to the stove electrical requirements 230V 50Hz and 350Watt Make sure the electrical cord doesn t get in touch with any hot part of the stove doesn t run over...

Страница 30: ...fy that the pellet tank is sufficiently charged for the desired ignition period Verify that the grille surrounding the brazier is in place Check that the door and the pellet loading door are tightly c...

Страница 31: ...e baffle plates as follows ANNUAL CLEANING Helical turbulator inside the smoke channel where present Combustion chamber Smoke deflectors Lower smoke chamber Seals Flue connection duct Fans Air intake...

Страница 32: ...each model by consulting the specifications of each instruction Air fireplaces with front or side glass Mod APOLLO 15 SERBIS M14 SERBIS EVO M14 ORION 13 FRATAC M14 FRATAC EVO M14 SIRIUS 11 ROBIN M11...

Страница 33: ...cas d un service en dehors de la p riode de garantie tous les frais de pi ces main d uvre et de d placement sont pris en charge par le client 7 La garantie ne couvre que les d fauts du produit qui d t...

Страница 34: ...ionnement ult rieur du produit install Il faut respecter toutes les lois et r glementations europ ennes nationales r gionales provinciales et communales existant dans le pays o a t install l appareil...

Страница 35: ...ments de l emballage la port e des enfants ou de personnes handicap es non assist s Contr ler la pr sence ventuelle d obstructions avant d allumer un appareil apr s une longue p riode d inactivit L ap...

Страница 36: ...LLATION La mise en uvre d un appareil granul s doit tre r alis e en conformit avec la r glementation en vigueur et l ensemble des documents fournis avec l appareil Toutes les r glementations locales e...

Страница 37: ...comme des meubles en bois des rideaux des tapis et des liquides inflammables au moins 100 cm de l appareil en fonctionnement DISTANCES MINIMALES DES MAT RIAUX NON INFLAMMABLES Dans le cas de mat riau...

Страница 38: ...qui pousse l air chaud vers 2 sorties sup rieures de 150 mm mod les SERBIS M14 FRATAC M14 SIRIUS 11 et ROBIN M11 ou de 80 mm dans les mod les APOLLO 15 SERBIS EVO M14 ORION 13 FRATAC EVO M14 qui doive...

Страница 39: ...ous les composants d au moins 50x140 cm de hauteur La porte pourrait galement tre faite l arri re ou sur le c t permettant l acc s tout l int rieur du foyer 3 4 CANAL SUP RIEUR DE VENTILATEUR AIR CHAU...

Страница 40: ...s pour chauffer l air de la pi ce Un ventilateur centrifuge sup rieur droit de 180 m3 h avec une sortie d air chaud de 60 mm pouvant tre parcourue jusqu une distance maximale de 5 m tres g rable par l...

Страница 41: ...onsabilit pour les fuites d eau des raccords 14 D FLECTEURS SUP RIEURS Chaque appareil peut avoir des d flecteurs de fum e en vermiculite placer dans la partie sup rieure de la chambre de combustion L...

Страница 42: ...quement des conduits isol s pour Pour toutes les chemin es l ext rieur de la maison dans les greniers greniers non chauff s des tron ons tr s longs dans l habitation plus de 4 m tres A diam tre de la...

Страница 43: ...xt rieur l humidit venant de l ext rieur en fait emp che les granul s sont allum s et pourrait donner des probl mes la bougie de pr chauffage AVERTISSEMENT Les ventilateurs d aspiration m caniques VMC...

Страница 44: ...huiles sur les composants Ventiler la pi ce et ne pas rester jusqu ce que les odeurs soient termin es La peinture utilis e est base d eau totalement exempte de substances toxiques volatiles pour vous...

Страница 45: ...as pulv riser directement le produit de nettoyage sur la vitre mais seulement sur le drap utilis Les agents chimiques de nettoyage utilis s ne doivent pas fuir ou stagner sur la partie du verre s rigr...

Страница 46: ...e ramonage m canique du conduit de fum e est obligatoire il doit tre r alis au moins deux fois par an dont une fois au moins pendant la saison de chauffe Un certificat doit tre remis par l entrepreneu...

Страница 47: ...L ARTISTICO SRL FR 47 Cod 40115 Rev 12 08 08 2019 Chemin e air avec vitre vertical Mod Starfire Chemin es Idro Mod MARLIN...

Страница 48: ...istenza contattate il centro assistenza autorizzato o il vostro rivenditore For information and help Pour plus d informations et de l aide Produttore Producer L ARTISTICO S R L VIA NAZIONALE 2 25080 R...

Отзывы: