The explanations provided must be read by any personnel who
will operate the system.
If the system functions in a different manner with
respect to the information which has been inserted,
the user is advised to communicate the event to
the manufacturer so that a technician may verify
the program which has been loaded onto the PLC.
Use the 4 arrow buttons to the right of the display to navigate
within the selected screen.
Procedure for selecting a field to modify:
• use the arrow buttons to select the desired field ;
• activate the field by pressing ;
• modify the set value with the and arrows;
• press the button to confirm the entry.
OPERATING PANEL
The operating panel is connected to the system and is used for:
• inserting and viewing process variables;
• viewing alarms and signals in order for the operator to easily
identify them while the system is in function;
• selecting the desired function in manual mode.
CONTROL PANEL
The Control panel (
I1
) is used in conjunction with the Operating
Panel by the user to control machine function, to select the cycles
(manual, automatic)
and functionalities, as well as for immediately
viewing the system’s functional status.
The light on the panel indicates whether any alarms are active.
ALARM CHECKS
The PLC reacts in the following manner to every alarm event:
• The red light (
I2
) installed upon the control panel flashes;
• The operating panel displays the text which corresponds to the
alarm.
The functionality in question which has generated the alarm is
blocked until the anomaly has been fixed.
To cancel the alarm, do the following:
• resolve the situation which caused the alarm;
• press the F4 button on the alarm screen to reset the alarm;
• press the ACK alarms button to remove the alarm from the panel;
The system will not allow an alarm to be reset if the situation which
caused the alarm has not been resolved.
Some alarms are automatically reset once the situation which
caused the alarm has been resolved.
POWER STATUS
The power status is indicated
by a green light located on the
system’s ON/OFF selector.
I1
I2