17
NOVA MIX 2K
English
G1
G2
G3
G5
G5
G7
G8
OPEN
G7 - G8
CLOSE
G9
G10
G7 - G8
G9 - G10
OPEN
STARTING UP AND CHARGING THE MACHINE
1
. Fill the tanks (
G1
) and (
G2
) with the materials necessary
for processing. For versions without tanks, directly introduce
floaters into the containers (
G3
).
G
2
. After connecting the machine to the power, press the side
switch (
G4
) located on the control panel in position “
I
".
3
. Power the pumps with compressed air and set the two regu-
lators to minimum (
G5
) and (
G6
).
4
. Open the recirculation valves (
G7
) and (
G8
) allowing the
product to begin recirculation.
☞
NOTE
If you are not sure that the first part of the product is properly
cleaned, discharge the first part, which starts to recirculate outside
the tanks, to avoid contaminating the clean product.
5
. Close the recirculation valves (
G7
) and (
G8
).
WORKING
6. Open the delivery valves (
G9
) and (
G10
).
G4
MIN