15
NOVA MIX 2K
English
CONNECTING THE EQUIPMENT TO THE PNEUMATIC LINE
☞
NOTE
Adjust all regulators to the working pressure (
F25
).
To avoid electric shock when disassembling or checking the elec-
tronic equipment, wait 5 minutes after having disconnected the
power supply cable, so that the electricity stored in the condensers
while working can be dissipated.
Also check the condition of the earth cable to avoid any risk of shock.
Before carrying out any checks on the machine
(maintenance, cleaning, or replacing parts)
switch
off the machine and wait until it has stopped
altogether.
While checking stay away from electrical or moving
parts to avoid any risk of shock or crushing of hands.
WARNING
:
•
DO NOT modify the plug for the earth socket
in any way.
•
ONLY use electrical connections that are
earthed.
•
Make sure that any earth extension cords are
in good condition.
•
ONLY use three-core extension cables.
•
Avoid direct contact with the rain. Keep the
equipment in a dry place.
The machine must be connected to the compressed air feeding
system, which is necessary for the pneumatic interlocking.
The connection must be carried out in the following way:
• Connect the air feeding pipe (
F21)
to the joint (
F22
).
It is advisable to install an on-off valve on the frontal
part of the machine
Make sure that the air line to be connected to the machine is
capable of constantly providing pressure at 7 bar.
Before opening the air line, turn the ball valve (
F23
) on the general
regulator (
F24
) to its closed position.
After having opened the machine's air supply, open the ball valve
completely (
F23
) and set the regulator to maximum (
F24
).
F20
F24
F23
F21
F22
F25