5: Configuration via Serial Mode or Telnet Port
WiPort® NR Embedded Device Server User Guide
32
5. The configuration settings display, followed by the setup menu options:
Figure 5-2. Setup Menu Options
Change Setup:
0 Server
1 Channel 1
2 Channel 2
3 E-mail
5 Expert
6 Security
7 Defaults
8 Exit without save
9 Save and exit Your choice ?
6. Select an option on the menu by entering the number of the option in the
Your
choice
?
field and pressing
Enter
.
7. View the current configuration by pressing
Enter
from the Change Setup menu.
8. To enter a value for a parameter, type the value and press
Enter
. To confirm a
current value, press
Enter
(without inputted parameters).
9. When finished, save the new configurations (
9 Save and exit
). The unit reboots.
Serial Port Access
To configure the unit through a serial connection:
1. Connect a console terminal or PC running a terminal emulation program to your
unit's serial port. The default serial port settings are 9600 baud, 8 bits, no parity,
1 stop bit, no flow control.
2. Reset the WiPort NR unit by cycling the unit's power (turning the power off and
back on). Immediately upon resetting the device, enter three lowercase
x
characters (
xxx
).
Note:
The easiest way to enter Setup Mode is to hold down the
x
key at
the terminal (or emulation) while resetting the unit. This must be done
within three seconds of resetting the WiPort NR embedded device
server.
3. Upon connection, the following information displays:
Figure 5-3. MAC Address
MAC address 00204AFFFF30
Software version V6.9.0.4 (130628)
Press Enter to go into Setup Mode
4. To enter the Setup Mode, press
Enter
within 5 seconds.
Note:
Connection fails if
Enter
is not pressed within 5 seconds.