4: Using DeviceInstaller
UDS1100 User Guide
20
Web Port
Non-configurable field. Displays the UDS1100’s port for Web-
Manager configuration.
Maximum Baud Rate
Supported
Non-configurable field. Displays the UDS1100’s maximum
baud rate.
Note:
The UDS1100 may not currently be running at this rate.
Firmware Upgradeable
Non-configurable field. Displays
True
, indicating the
UDS1100’s firmware is upgradeable as newer version
become available.
Supports Configurable
Pins
Non-configurable field. Displays
False
.
Supports Email Triggers
Non-configurable field. Displays
False
.
Supports AES Data
Stream
Non-configurable field. Displays
False.
Supports 485
Non-configurable field. Displays
True.
UDS1100 supports the
RS-485 protocol.
Supports 921K Baud
Rate
Non-configurable field. Displays
False
. UDS1100 supports
baud rates up to 230 Kbaud.
Supports HTTP Server
Non-configurable field. Displays
True
.
Supports HTTP Setup
Non-configurable field. Displays
True
.
Supports 230K Baud
Rate
Non-configurable field. Displays
True
. UDS1100 supports a
baud rate of 230400.
Supports GPIO
Non-configurable field. Displays
False
, indicating the
UDS1100 does not support General Purpose Input Output
(GPIO).
Next Step
Now that the UDS has an IP address and other initial settings, you can configure it.
1. Double-click the unit in the list. Details about the unit display.
2. You have the following options:
To configure the unit using a Web browser, click the
Web Configuration
tab.
The Lantronix Web-Manager window displays in your browser. Continue with
5: Configuration Using Web-Manager
.
Note:
To assign Expert and Security settings, you must use the Setup
Mode window in a Telnet session.
To configure the unit using a Telnet session, click the
Telnet Configuration
tab.
The Setup Mode window displays. Continue with
6: Configuration via Telnet or
Serial Port (Setup Mode)
.