SCSxx05/SCSxx20 User Guide
8: Commands
8-8
Device Name
The device name cannot contain a space. Use an underscore if you need an
empty space in the name.
Baud Rate
Seven device baud rates are offered: 2400, 4800, 9600, 19200, 38400, 57600,
and 115,200. Most devices use 9600 as the terminal/administration port's baud
rate, so the device port defaults to this value. Check the equipment settings and
documentation for the proper baud rate.
Stop Bits, Parity, Data Bits
The stop bits, parity, and data bits parameters determine the format of the bit-
wise transmission of data. The default settings are 1 stop bit, no parity, and 8
data bits. Check your equipment documentation for the proper settings.
DCE/DTE
The SCSxx05 device and terminal ports are factory configured as DTE devices.
The SCSxx20 device and terminal ports are factory configured as DCE devices.
Flow Control
The device port flow control setting determines the method of flow control.
The two most common settings are XON/XOFF (software) and RTS/CTS
(hardware). The default setting for the device ports is XON/XOFF. Check the
equipment documentation for the correct flow control setting.
Buffering
The Inhibit Buffering in Direct setting allows the administrator to turn off port
buffering while a user is connected to the device and is in direct mode. The
device port buffer still collects data while not in direct mode when this setting is
active. You may disable direct mode buffering so other users cannot view
sensitive data, but the system stores alert and panic messages from the attached
device when nobody is connected. This setting is disabled by default, so buffer
data is collected both in and out of direct mode.
connections
Use
connections
to display a snapshot list of all users connected in direct mode.
cat
Use
cat <port name or number>
to display the buffer information for that port.
clear
Use
clear <port name or number>
to clear the buffer for that port.
less
Use
less <port name or number>
to browse the buffer for that port. When the
buffer reaches the capacity of the screen, it pauses; press the spacebar to
continue the display. When the buffer reaches the end, it displays "END"; press
q
to quit the
less
program and return to the command line.
logout
Use
logout
to quit your session with the system.
Содержание SCSxx05
Страница 10: ...ix ...
Страница 11: ...x ...
Страница 12: ...xi ...
Страница 13: ...xii ...
Страница 14: ...xiii ...
Страница 15: ...xiv ...
Страница 47: ...SCSxx05 SCSxx20 User Guide 4 Configuration 4 7 ...
Страница 127: ...SCSxx05 SCSxx20 User Guide C Pinouts and Adapters C 7 RJ45 Receptacle to DB9M DTE Adapter for the SCSxx05 Part 200 2071 ...
Страница 128: ...SCSxx05 SCSxx20 User Guide C Pinouts and Adapters C 8 RJ45 Receptacle to DB9F DTE Adapter for the SCSxx05 Part 200 2072 ...