SCSxx05/SCSxx20 User Guide
4: Configuration
4-5
7. To enter the list of TCP Public Services that the SCS should support, edit the
text-entry list from the choices indicated in the
Answer
field (ftp-data, ftp,
SSH, telnet, www, and https).
Firewall.conf
What is the value for TCP_PUBLIC_SERVICES?
This is the list of ports we allow TCP connections to.
Answer: ssh telnet https
For example, you may choose to remove
telnet
from this list of services
for security reasons, leaving only ssh and https .
What is the value for TCP_PUBLIC_SERVICES?
This is the list of ports we allow TCP connections to.
Answer: ssh https
8. Press
the
Esc
key to end the editing, and press
Enter
. The UDP public
services prompt displays
9. To identify the UDP public services to be supported, enter the services
required for your configuration in the
Answer
field.
What is the value for UDP_PUBLIC_SERVICES?
This is the list of ports we allow UDP connections to.
Answer: ntp
10. Press the
Esc
key to end text entry, and press
Enter
to continue. The setup
menu returns with
Configure Device Ports
selected.
Configuring Device Ports
Note:
It is generally not necessary to change the configuration of the
terminal port, other than its data rate. Therefore, no options are available
on the setup menu or Web interface for changing its configuration. If you
need to make a change, use the
dtedce
command to change the DTE or
DCE setting, and use the buttons on the front panel to change the baud
rate (see
Method #1 – Using the Front Panel Display
).
The
Configure Device Ports
option on the setup menu is actually a script
running within the setup script. Therefore, some of its processes are different
from those of other options.
Done
in the Configure Device Ports routine
causes your changes to be written to the flash memory
. This is different from
Done
at the end of the setup menu list, which just prepares the entries to be
saved. Also,
<Back>
navigation is disabled in some places.
Содержание SCSxx05
Страница 10: ...ix ...
Страница 11: ...x ...
Страница 12: ...xi ...
Страница 13: ...xii ...
Страница 14: ...xiii ...
Страница 15: ...xiv ...
Страница 47: ...SCSxx05 SCSxx20 User Guide 4 Configuration 4 7 ...
Страница 127: ...SCSxx05 SCSxx20 User Guide C Pinouts and Adapters C 7 RJ45 Receptacle to DB9M DTE Adapter for the SCSxx05 Part 200 2071 ...
Страница 128: ...SCSxx05 SCSxx20 User Guide C Pinouts and Adapters C 8 RJ45 Receptacle to DB9F DTE Adapter for the SCSxx05 Part 200 2072 ...