SCSxx05/SCSxx20 User Guide
2: Installation
2-4
Connecting to a Device Port
You can connect any device that has a serial console port to the SCS for
consolidated remote administration. You can configure the device ports
individually. The console port must support the RS-232C interface. Additionally,
many servers must either have the serial port enabled as a console, or must
have the keyboard and mouse detached. Consult the server hardware and/or
software documentation for more information.
Figure 2-5. Connections on Rear of SCS4805 (Mostly Device Ports Using RJ45 Connectors)
The default communication parameters for the device ports are:
9600 baud
8 data bits
1 stop bit
No parity
XON/XOFF flow control
DTE port type
You can configure each device port individually with the following values:
Baud rates: 2400, 4800, 9600, 19200, 38400, 57600, or 115200 baud
Note:
We recommend using baud rates of 57600 or less for
optimal performance.
Data bits: 6,7, or 8
Stop bits: 1 or 2
Parity: none, odd, even, mark or space
Flow control: XON/XOFF or RTS/CTS
Port type: DTE or DCE; a port may also be disabled
Buffering: may be inhibited on a port-by-port basis
Содержание SCSxx05
Страница 10: ...ix ...
Страница 11: ...x ...
Страница 12: ...xi ...
Страница 13: ...xii ...
Страница 14: ...xiii ...
Страница 15: ...xiv ...
Страница 47: ...SCSxx05 SCSxx20 User Guide 4 Configuration 4 7 ...
Страница 127: ...SCSxx05 SCSxx20 User Guide C Pinouts and Adapters C 7 RJ45 Receptacle to DB9M DTE Adapter for the SCSxx05 Part 200 2071 ...
Страница 128: ...SCSxx05 SCSxx20 User Guide C Pinouts and Adapters C 8 RJ45 Receptacle to DB9F DTE Adapter for the SCSxx05 Part 200 2072 ...