8: Line and Tunnel Settings
PremierWave® XN Intelligent Gateway User Guide
83
Initial Send
Enter the Initial Send string indicating whether it is in Text or Binary form. This
Initial Send data will be sent out to the network upon connection
establishment, before any data, from the Line. It may contain one or more
directives in the form
%<char>
.
The binary form allows square braces [] to enclose one or more character
designations separated by commas. Use straight decimals up to 255 or
hexadecimal numbers prefixed with
0x
up to
0xFF
within the square braces.
To specify an open brace in binary mode, use two in a row. Example (in
binary mode):
AB[255,0xFF[C[[D]
results in a string contaiing binary
values where the dots appear:
AB..C[D]
.
Directives:
%i
local IP address
%m
MAC address
%n
network interface name
%p
local port
%s
serial number
%%
%
Flush Serial
Set whether the serial line data buffer is flushed upon a new network
connection. Choices are:
Enabled
= serial data buffer is flushed on network connection
Disabled
= serial data buffer is not flushed on network connection (
default
)
Block Serial
Set whether Block Serial is enabled for debugging purposes. Choices are:
Enabled
= if Enabled, incoming characters from the serial line will not be
forwarded to the network. Instead, they will be buffered and will eventually
flow off the serial line if hardware or software flow control is configured.
Disabled
= this is the default setting; incoming characters from the Serial
Line are sent on into the network. Any buffered characters are sent first.
Block Network
Set whether Block Network is enabled for debugging purposes. Choices are:
Enabled
= if Enabled, incoming characters from the network will not be
forwarded to the Serial Line. Instead, they will be buffered and will
eventually flow off the network side.
Disabled
= this is the default setting; incoming characters from the network
are sent on into the Serial Line. Any buffered characters are sent first.
Password
Enter a password. This password can be up to 31 characters in length and
must contain only alphanumeric characters and punctuation. When set,
clients must send the correct password string to the unit within 30 seconds
from opening network connection in order to enable data transmission. The
password sent to the unit must be terminated with one of the following:
0A (Line Feed)
00 (Null)
0D 0A (Carriage Return/Line Feed)
0D 00 (Carriage Return/Null)
If,
Prompt for Password
is set to
Enabled
and a password is provided, the
user will be prompted for the password upon connection.
Email on Connect
Select an email profile number to which an email notification will be sent upon
the establishment of an accept mode tunnel.
Email on Disconnect
Select an email profile number to which an email notification will be sent upon
the disconnection of an accept mode tunnel.
Tunnel Accept Mode
Settings (continued)
Description