7: Network, Serial Line, Tunnel, and Modbus Settings
IntelliBox-I/O 2100 User Guide
73
Table 7-10 Tunnel – Modem Emulation Page
Tunnel – Modem
Emulation Page
Settings
Description
Echo Pluses
Select whether the modem +++ escape sequence is echoed
(sent). Choices are:
On
= modem pluses are sent into the network.
Off
= modem pluses are suppressed. (default).
Echo Commands
Select whether modem commands are echoed on the serial line.
Choices are:
On
= modem commands are echoed. (default)
Off
= modem commands are not echoed.
Verbose Response
Codes
Select whether modem response (result) codes are sent on the
serial line. Choices are:
Text
= modem responses are sent on the serial line. (default)
Numeric
= modem responses are not sent.
Response Codes
Select whether modem response (result) codes sent on the serial
line take the form of words or numbers. Choices are:
Text
= modem responses are sent as words. (default)
Numeric
= modem responses are sent as numbers.
Error Unknown
Commands
Select whether an ERROR or OK response is sent in reply to
unrecognized AT commands. Choices are:
On
= ERROR is returned for unrecognized AT commands.
Off
= OK is returned for unrecognized AT commands. (default)
Incoming Connection
Select how to manage incoming requests. Choices are:
Disabled
= disable requests (ATS0=0)
Automatic
= automatically answer requests (ATS0=1)
Manual
= manually answer requests via the ATA command after
an incoming RING (ATS0=2)
Connect String
If required, enter a customized string that is sent along with the
CONNECT response code. Default is <none>.
Display Remote IP
Select whether to enable an incoming RING followed by the IP
address of the caller. Choices are:
Enabled
Disabled
Содержание I/O 2100
Страница 1: ...Part Number 900 474 Revision B March 2012 IntelliBox I O 2100 User Guide ...
Страница 36: ...5 Getting Started IntelliBox I O 2100 User Guide 36 Figure 5 1 Lantronix DeviceInstaller ...
Страница 86: ...9 Services Settings IntelliBox I O 2100 User Guide 86 Figure 9 7 HTTP Configuration Page ...
Страница 95: ...10 Security Settings IntelliBox I O 2100 User Guide 95 Figure 10 1 SSH Server Host Keys Page ...
Страница 123: ...12 Advanced Settings IntelliBox I O 2100 User Guide 123 Figure 12 3 Email Configuration Page ...
Страница 182: ...E Isolated I O Specifications IntelliBox I O 2100 User Guide 182 Figure C6 Relay Contact position when energized ...