4: Installation
IntelliBox-I/O 2100 User Guide
32
Table 4-4 Digital I/O Pins
Pin #
Pin Name
Description
1
1+
2-wire configurable digital IO, positive contact, 1st port
2
1-
2-wire configurable digital IO, negative contact, 1st port
3
2+
2-wire configurable digital IO, positive contact, 2nd port
4
2-
2-wire configurable digital IO, negative contact, 2nd port
Relay Port
A 3-terminal relay-controlled dry contact NC, COM, NO (up to 8A) is on the front of the
unit. The relay is for SELV applications only (UL Class III or Class 2). The relay contacts
are isolated from the inner circuit of the IntelliBox.
Pin 1 = COM, PIN 2 = NO, PIN 3 = NC due to recent change
Table 4-5 Relay Port Pins
Pin #
Pin Name
Description
1
COM
Common contact
2
NO
Normally open when power ON (closed to COM when power is OFF)
3
NC
Normally closed to COM when power ON (open when power is OFF)
LEDs
The IntelliBox has the following LEDs:
Table 4-6 Ethernet Port LEDs
LEDs
Descriptions
Left – Green ON
Link Established – 100BASE-T
Left – Amber ON
Link Established – 10BASE-T
Right – Green ON
Full Duplex (Blinking = Activity)
Right – Amber ON
Half Duplex (Blinking = Activity)
Table 4-7 LEDs on Top Cover
LEDs
Descriptions
Power/Diagnostic - Blue
Power Indicator and Diagnostic
RX Serial 1 - Green
Serial 1 Received Data Activity
TX Serial 1 - Amber
Serial 1 Transmitted Data Activity
RX Serial 2 - Green
Serial 2 Received Data Activity
TX Serial 2 - Amber
Serial 2 Transmitted Data Activity
Содержание I/O 2100
Страница 1: ...Part Number 900 474 Revision B March 2012 IntelliBox I O 2100 User Guide ...
Страница 36: ...5 Getting Started IntelliBox I O 2100 User Guide 36 Figure 5 1 Lantronix DeviceInstaller ...
Страница 86: ...9 Services Settings IntelliBox I O 2100 User Guide 86 Figure 9 7 HTTP Configuration Page ...
Страница 95: ...10 Security Settings IntelliBox I O 2100 User Guide 95 Figure 10 1 SSH Server Host Keys Page ...
Страница 123: ...12 Advanced Settings IntelliBox I O 2100 User Guide 123 Figure 12 3 Email Configuration Page ...
Страница 182: ...E Isolated I O Specifications IntelliBox I O 2100 User Guide 182 Figure C6 Relay Contact position when energized ...