13: EventTrak Pages
IntelliBox-I/O 2100 User Guide
149
EventTrak Control
Step A Settings
Description
in response to an event.
Trigger task x
triggers an event on another task in the
same EventTrak.
Trigger EventTrak x Task 1
triggers an event on Task 1
in a different EventTrak (e.g., serial line 1 EventTrak can
trigger an event on serial line 2 EventTrak).
Fallback to Step "A" if
From the
Add an Event
drop-down list, select one or more events
that will trigger EventTrak to fall back (return) to Step "A," the
beginning of the task. When you select an option,
Upon Fallback
displays.
Note:
You can select more than one event to trigger a
fallback to step "A," but you must open the drop-down list
and select one at a time.
Timeout expires
= tells EventTrak to wait a configurable amount of
time before falling back. This is useful when you want to pause
EventTrak to wait for an event or gather serial data for automated
reporting. Select to configure as milliseconds, seconds or minutes.
The maximum length of a timeout is 7 days (10080 minutes)
Line outputs data
=falls back if data is sent out the serial port
Tunnel accepts connection
= tells EventTrak to fall back if the
IntelliBox accepts a TCP connection to its serial port
Tunnel accepts disconnection
= tells EventTrak to fall back event
if a TCP connection to the IntelliBox's serial port is disconnected
Ping Response
= tells EventTrak to fall back if it receives a ping
response. Use this option in conjunction with the initial action of
Send a ping
.
Match String “x”
= tells EventTrak to monitor the serial port and fall
back if it detects a specific string. The choices are
Match String 1
,
Match String 2
or
Match String 3.
(See
EventTrak – Monitoring
Page
for instructions on defining match strings.)
Triggered by task “x”
= enables EventTrak to fall back when
another task instructs it to continue.
Upon Fallback
From the drop-down list, select the action EventTrak should take
when the IntelliBox detects an event that will cause EventTrak to fall
back to Step “A”. The
Upon Fallback
box displays when you
configure
Fallback to Step “A”
. Choices are:
No Trigger
=
no trigger is fired upon fallback to Step “A”
Fire Trigger to Task x
=t ells EventTrak to trigger an event on
another task. For example, you can set
Upon Fallback
on Task 1 to
trigger an event on Task 2. Task 2 can be triggered by setting its
Advance to
or
Fallback to
configurable to
Triggered by task 1
.
Note:
For examples of using EventTrak for event monitoring and automated reporting,
please go to
http://www.lantronix.com/support
.
Содержание I/O 2100
Страница 1: ...Part Number 900 474 Revision B March 2012 IntelliBox I O 2100 User Guide ...
Страница 36: ...5 Getting Started IntelliBox I O 2100 User Guide 36 Figure 5 1 Lantronix DeviceInstaller ...
Страница 86: ...9 Services Settings IntelliBox I O 2100 User Guide 86 Figure 9 7 HTTP Configuration Page ...
Страница 95: ...10 Security Settings IntelliBox I O 2100 User Guide 95 Figure 10 1 SSH Server Host Keys Page ...
Страница 123: ...12 Advanced Settings IntelliBox I O 2100 User Guide 123 Figure 12 3 Email Configuration Page ...
Страница 182: ...E Isolated I O Specifications IntelliBox I O 2100 User Guide 182 Figure C6 Relay Contact position when energized ...