Tunnel – Disconnect Mode Page
If you click
Disconnect Mode
at the top of one of the Tunnel pages, the Tunnel –
Disconnect Mode page displays. Here you can select the disconnect method for the
tunnel selected at the top of the page. For more information about Disconnect Mode, see
Disconnect Mode
.
Figure 7-10 Tunnel – Disconnect Mode Page
Table 7-8 Tunnel – Disconnect Mode Page
Tunnel –
Disconnect Mode
Page Settings
Description
Character Stop
Select whether to enable disconnect when the “Stop Character”
(configured on the “Start/Stop Chars” page) is read on the serial line.
Choices are:
Enabled
Disabled
Modem Control
Select whether to enable disconnect when the modem control pin is not
asserted on the serial line. Choices are:
Enabled
Disabled
Timeout
Enter the idle time, in milliseconds, that must elapse for a connection
before it is disconnected. Default is 60000 milliseconds. The value 0
(zero) disables the idle timeout.
Flush Serial Data
Select whether the serial line should be flushed when a connection is
disconnected. Choices are:
Enabled
= flush the serial line when a connection is disconnected.
Disabled
= do not flush the serial line. (default)
Содержание I/O 2100
Страница 1: ...Part Number 900 474 Revision B March 2012 IntelliBox I O 2100 User Guide ...
Страница 36: ...5 Getting Started IntelliBox I O 2100 User Guide 36 Figure 5 1 Lantronix DeviceInstaller ...
Страница 86: ...9 Services Settings IntelliBox I O 2100 User Guide 86 Figure 9 7 HTTP Configuration Page ...
Страница 95: ...10 Security Settings IntelliBox I O 2100 User Guide 95 Figure 10 1 SSH Server Host Keys Page ...
Страница 123: ...12 Advanced Settings IntelliBox I O 2100 User Guide 123 Figure 12 3 Email Configuration Page ...
Страница 182: ...E Isolated I O Specifications IntelliBox I O 2100 User Guide 182 Figure C6 Relay Contact position when energized ...